1 vote
296 views

This icemaker won’t make ice. It fills but doesn’t harvest cubes.

  • Pancakes asked 6 months ago
  • last active 6 months ago
0 votes
413 views

What are the reasons the capacitor keeps blowing? And how do you test them? The motor runs, the agitator moves freely and so does the drum. The drain pump is clear.

  • SiNRG asked 8 months ago
  • last active 8 months ago
0 votes
457 views

The refrigerator does not cool consistently. Customer stated they’ve been having power surges. The refrigerator seems to cool and work for a couple hours then shuts off, will get to 65 in the refrigerator, then will starts working again. Food spoils. Customer unplugged unit for a while and plugged back in. Damper is open can feel air flow, fan is working. Tested thermistor 11.15 k ohms, How do we test the control board, and what should the thermistor be testing at?

0 votes
380 views

How much ice should this refrigerator produce in a 24 hour period?

0 votes
435 views

Customer put a standalone thermometer in refrigerator section. Temperature goes from 50 to 37 degrees. Is this normal or does the main PCB need to be replaced.

0 votes
587 views

I replaced the right front burner element and am getting F5 and the right front burner heats up without being turned on.

  • kochese asked 1 year ago
  • last active 1 year ago
0 votes
808 views

The drum will spin by itself, but can easily be stopped. It will not spin clothes dry on heavier loads and medium loads. What would be causing it to spin but not spin clothes dry? I would think this is a thrust bearing but it looks like it does not have one.

0 votes
999 views

CUSTOMER CALLED US ORIGINALLY BECAUSE THE FRIDGE WASNT COOLING. WE REPLACED THE MAIN CONTROL BOARD ON THIS UNIT AND IT BEGAN TO COOL WITH NO ISSUE. NOW THE REFRIGERATOR IS NOT MAKING ICE. WE HAVE REPALCED THE ICEMAKER BUT IT WONT CYCLE OR MAKE ICE. WE PUT IT INTO DIAGNOSTIC MODE AND UNDER THE ICE MAKER DIAGNOSTIC THEN IT CAME UP WITH ERROR CODE “23”. WE NEED TO SEE WHAT THIS MEANS AND WAHT THE REPAIR IS FOR THE CODE.

0 votes
1k views

When you press bake to preheat upper oven broil element stays on.
When you press bake to preheat lower oven Broil element does not come on only bake element

I need service manuel to change out relay board

  • Loinest76 asked 2 years ago
  • last active 2 years ago
0 votes
1k views

This unit has a failed compressor and it states we have to update the board on this unit. Do you have any instructional materials, or guides on how to complete this common LG compressor repair. Kenmore Refrigerator – LG BUILT

1 vote
1k views

This dryer is not coming on . I have test power and it is 240 on L1 and L2 but when i test on L1 to neutral i get 120 with is good but when i test L2 to N i am get 240 but only when dryer is plug up to wall plug . Test at wall plug is fine 240 L1 to L2 and 110 for L1 to N and L2 to N 110
This is crazy it has a new main board installed .

What do you thank mite be the cause that is keeping the dryer for working

  • kc0otv73 asked 3 years ago
  • last active 3 years ago
0 votes
828 views

How do I put this refrigerator into manual defrost?

0 votes
2k views

I have replaced the display panel already and the problem is persisting.
The digital user interface is inoperable. The light and temperature setting cannot be adjusted, also cannot dispense water or ice. Have replaced user interface and it worked for a week and then did the same thing and stopped working. If you unplug the refrigerator and plug it back in it works for 5 minutes then stops being responsive. The temperature is fine in the refrigerator and freezer. Would this be the main control board for the unit?

0 votes
3k views

Software rewrite keeps showing Up date failed, on the manual mode it doesn’t show compressor info as FLSO75LANA.

0 votes
1k views

Snow-like frost build up on evaporator cover. Will take cover off and defrost, then two days later it is built back up again. It is not a frost pattern concurrent with the fridge being low on freon.

0 votes
1k views
  • daves28 asked 4 years ago
  • last active 4 years ago
0 votes
2k views

I replaced the door latch. It takes a while before it releases after stopping or finishing a load and will not unlock for a while, it just keeps clicking.

  • Guest asked 4 years ago
  • last active 4 years ago
0 votes
1k views

Washer fills then sets off tE error and eventually drains. No spin. Need tech sheet.

  • RBair asked 4 years ago
  • last active 4 years ago
0 votes
1k views

I will not get any error codes in diagnostic mode but the spin cycle is extremely loud and washer is now leaking. Is there a video that can help me out with this? Also when I put on a regular cycle it doesn’t always go into spin.

1 vote
2k views

On this Kenmore Elite range the RF burner stays on at all times. From what I can see the controller is what controls this function (316576311) . Can you verify, and also tell me if there are any other potential causes.

0 votes
2k views

Kenmore SxS ref.; Control panel beeps, temperature numbers on panel changing every second, Different numbers blinking. actual temperatures are okay, when I get there everything working. need service manual or tech. sheet
kenmore SxS model # 106.44323400

  • joeski1369 asked 5 years ago
  • last active 5 years ago
0 votes
2k views

Code11 shows up, which is the MCU. How can I check to make sure that is what is wrong. Kenmoe Elite HE4T

0 votes
2k views

Customer had F-20 code. Replaced fill valve and customer claims that they still get code on normal wash only, not on quick wash. Unplugged unit and left for an hour than plugged back in. Same problem remains. Any ideas?

  • appliance7 asked 5 years ago
  • last active 5 years ago
0 votes
2k views

correct voltage at terminal block. Turn on control. what ever cycle when start is pressed. control shows dryer operating. door switch, thermals and belt switch check ok. Don’t know where to read voltages at motor. and not sure where on control is the motor circuit.

0 votes
2k views

Evaporator fans not running. Freezer fan will run intermittently. Both will run if test button is pressed once on the board. Is it a board problem or something else?

0 votes
2k views

Do you have the Service manual for this refrigerator ?

  • 868877 asked 5 years ago
  • last active 5 years ago
0 votes
2k views

I have a Kenmore gas range that after replacing the spark module oven works ok except when you turn the oven on if you try to turn the gas burners on the display goes off and the oven shuts down. If you turn only the top burners on they work fine only if you turn the oven then it shuts off oven doesn’t heat. What can I check

0 votes
2k views

Do you have the service manual for this washer?

1 vote
2k views

When in the spin cycle you hear it try go spin like a car racing it’s engine then after three sports it just stops and the basket just glkeds to a stop she the drain is still running (I did here some clicking from the control board at the same time)
Which part needs to be fixed

  • Kevinv asked 5 years ago
  • last active 5 years ago