1 vote
3k views

in some refrigerators and replaced compressors, evaporators, condensers … the internal leak I think is a common problem of these refrigerators

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
1k views

Hello, Please read the Question carefully. This top load washer is about 5yrs old. Goes off balance almost every load. The Ue code will show. Start a cycle, it fills ,agitates, then after a few minutes starts spinning in one direction with water in the tub. Bang, Bang, Bang. Stops and starts agitating again. Bangs with clothes or no clothes. When it is in a spin cycle, after a while UE shows up even with no clothes in it. The tub bearings are good. The tub nut is tight. The rotor is not loose. Can hear water in the balance ring. Washer is level. Had one do this in the past, I changed the suspension rods. Still did the same thing. I asked this same question 2Yrs ago. suggested change control & rotor before 2014, and rotor only after 2014. This doesnt sound right for the problem I’m having. Then look at a video where you use rubber bands. Please, I need real help. This is a real common problem, I have seen 10 LG washers doing this. I dont know exactly what is causing the problem. The washer worked ok for 5yrs. Customer is not loading it improperly. When you come up with a solution please explain how or why this solution will fix the problem. Thank You, Jim

1 vote
2k views

I replaced ice tray and clip for thermister on tray. It is seating properly and firmly against the bottom of the ice tray. Ice maker actuated but when rotating tray 1/2 inch it hits Icemaker arm I suppose a switch inside arm tells Icemaker to return to original position.

I primed the ice tray with some water and it dumped the cubes in the bucket but did no subsequently fill with water.

I checked the water valve by temporarily moving the dispense connector on the water valve to the ice maker water valve and water flowed into ice tray when I pressed water dispense on outside of fridge.

How do I do an electronic fill test using diagnostic mode . I am buying Icemaker and would like to fully test before leaving the location .

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
1k views

I need a service manual. I have water to the back where the line goes into the filter (I suppose it’s to the filter)The Ice maker fills ok but there is not water to the dispenser. When I push the paddle I can hear the valve actuate but, Nothing. Is there a secondary valve some where? I couldn’t find it in the door . If so where is it?

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

there is power comeing to the unit.
and it goes to the computer board.
but then it stops.
I do not get any fans and light.
no display on the door water dispenser.
we are not getting any power

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
3k views

I STEEL HAVE PROBLEM REPLACED NEW COMPRESSOR AND MAIN PCB.I DID 3 TEST AND I DON,T HAVE ANY ERROR CODE.I FOUND OUT WHEN I PUSH ICE COLD MY COMPRESSOR RUNING AND I HAVE 320 V0LT AND DROW 1.6 AMP LOW SIDE PRESSURE IS -10PSI AND HIGH SIDE( DRYER)73PSI.RUNING 30 MINUTS AND I LIKE TO KNOW DO I HAVE BAD INVERTER BOARD NEED TO BE 80 TO 180 VOLT OR IS FREEON LOCK I DON,T HAVE GOOD FLOW HIGH SIDE IS TOO LOW PSI?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
1k views

I haven’t been on the call yet but I have an LG dryer that has a burning smell once it starts up

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

I AM TH NKING THIS MAY HAVE BEEN CAUSED BY CLOGGED UP VENT… OR POSSIBLY THE VENTED HOLES MAY ALSO BE CLOGGED OUTSIDE. NEED SOME IDEAS, BEFORE DIAGNOSING THIS MACHINE….

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
984 views

It will take as long as 4 to 5 minutes to come back on when (on the dual burner position) you go from low to high.

Is there an adjustment that can be made or is this a problem with the board? Which one?

Can you offer any advice? How do I test this kind of burner regulating system?

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

the flame will ignite however the the flame seems to be going out after 5 sec. i checked the vet for airflow and it is good.
i do not see any coils on the unit that i can replace

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The unit is making a loud humming noise like a fan. The lower freezer unit is not freezing. It is cold . The upper unit seems to be working. I put a thermometer in and the top part is staying at 33 degrees. No error codes on the unit.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
3k views

Customer gave no details of when the dishwasher gives the code, only that it reads the code: nE.

  • dwoods asked 4 years ago
  • last active 4 years ago
1 vote
2k views

Any suggestions on where to start for a soap dispenser that, after every cycle is full of water?

  • mytechjoe asked 8 years ago
  • last active 8 years ago
1 vote
1k views
1 vote
3k views

Left rail stuck.. freezer door will not open. Looks like rail is lock in mid Position

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
1k views

So I have this LG French door refrigerator. After a filter change it stopped getting cold enough to freeze and the refrigerator isn’t getting as cold as it’s set to. The freezer is getting to 48 degrees, the refrigerator is getting to pretty much the same, so something is working.

Take the lower cover off and clean up the coils and fan. I bumped the drain tube and it started spewing water out of the top. Let it finish draining, took the tube off and found a glob of something in there, so it was likely blocked (it was building up ice on the inside of the freezer that would have to be cleaned out from time to time). Hoped that would be the extent of things. Ran for about a day with no change.

Took the electronics cover off, the boards looked good as in no burnt stuff, fuses intact. Ran the first stage of the diagnostics and the display lit up everything. Fan running, I believe the compressor was running. Hard to tell with these linear condensers. It had a slight vibration to it. Second stage of the diagnostics, gave a 22 code on the front. Went to stage 3, fan and I’m guessing the compressor shut off like it was supposed to. Great. Reset everything and it comes back to life, fan running and slight vibration to the compressor. I will note the compressor did get warmer and i could feel a bit of cold in the copper.

After looking up the code and doing some research I’m thinking ok this is cake. So I take the lower panel back off and go to look at what I’m dealing with before I buy parts. well this model does NOT have a compressor relay. It’s got a compressor wire harness. @#%$@@%#$%^%

How do I fix an error 22 on this? or is the compressor junk?

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

oven won’t hold temperature , f7 error code

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

My dishes are still wet after the drying cycle.
What else we need to check to identify symptoms

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
3k views

LG Fridge Not getting cold everything tests ok new board installed not responding can hear compressor going and Tests ok installed 2 new boards same issue main boards that’s being installed is EBR78940612

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Would you be good enough to tell me what possible things I can do to fix the problem that I’m having with the LG Washer, can not turn on the power, and the display won’t come on.
Thanks Rich. rich9438@twc.com

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
1k views
1 vote
1k views

The fridge was not cooling I had an appliance tech come and test it he told me the compressor was bad as was the PCB. I replaced the PCB and the compressor. The old compressor had the two posts on top and one on bottom. I ordered my new compressor from sears with the part number and the one they sent me is the same part number but the posts are opposite one on top two on bottom. When I connected everything the condensor fan kicks on but nothing from the compressor no clicking nothing. Is the difference in the compressor causing the problem?

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
16k views

The refrigerator was not running. I look at the main board and observed the green light on the board blinking 6 times continuously after 3 seconds it blinks 6 times continuously. is it an error code or what. The tech sheet said nothing about the blinking light on the main board.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

I have a dishwasher that powers on and when you hit start it counts down lines go across the screen it sits for around 1 min and powers down any thoughts?

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
2k views

do you have a video on this lg dryer. how to get into

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views
       Customer complain is that when dryer is in any cycle but timed that the time remaining is wrong. Example 10 minutes remaining will be 25-30 minutes in real time.  Also on timed cycle that the clothes in her opinion come out to hot. She has to take them out right after cycle stops, to keep them from being wrinkled.  Thanks Ricky
1 vote
1k views

The water valve for this refrigerator is leaking. The problem is that the valve LG is saying that it needs is a MJX41178908, the mounting is perfect but this valve is a single solenoid valve. The original vale is a dual solenoid valve but they give no instructions to convert. I wanted to see if you have run into something like this before, get advice, or see if there is any instructions on this. There is another valve MJX41869202. THe valve that is in there is way different than both. Amy advice or research would be greatly appreciated.

1 vote
2k views

How can I put this refrig.. in defrost mode

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

No water I checked the primary valve its good but no voltage. I checked the ice and water valves inside the door. good and getting voltage. Not sure how this works but the circuit diagram shows the Pilot valve is powered from the main PCB and the ice and water valves are powered from the PWB Assembly Dispenser board. I have water to the Pilot valve ( The valve in back of the frig ) I emptied the water in the reservoir in the door. But still, the pilot valve is not energized. Do I need to get a PCB board or can you tell me why I get no water?

Thanks
Bill
Neighborhood appliance

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
2k views

SPECIFICALLY THE PROCEDURE TO RECHARGE THE SYSTEM AND SCHEMATIC.

TX

  • Guest asked 7 years ago
  • last active 7 years ago
Showing 1 - 30 of 905 results