0 votes
3k views

DOOR WONT LOCK AND MACHINE WONT DO ANYTHING, what is the most probable; door latch, control board or ?…
Thanks for your help

0 votes
3k views

GE wsm2700dawww makes loud clunking sounds when turning any recommendations ?

0 votes
3k views
0 votes
3k views
  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

G E range # JGS968SEK1SS ordered a new control board, installed now the range has a code LOC REF unplugged range powers up LOC REF
2 seconds than all the led lights on board on for 15 seconds, than LOC REF appears again cannot clear, can someone help me with issue.

0 votes
4k views

I have a GE ref model GFSS6KKYCSS, serial LT902433 Defrost drain tube for refrigerator (frost free section) is plugged. I used my steamer from the top and bottom (behind refrigerator by drain pan). The water in the ref was hot, but the water would not drain, so I don’t think it is ice blocking the tube. Tried sliding a wire through the drain tube, but the wire was stopped somewhere in the middle. Ran wire both ways thinking if something was in the tube, but no luck.
Is there anything else I can do? Is this drain tube accessible from any other place in the unit?

0 votes
3k views

I have a GE ref model PFCS1NFZCSS, serial ZV309662 Ice maker not making ice. part number WR30X10087. I do not see a manual switch to get this ice maker to go into a harvest mode. Freezer was at -2 F, so temp is not an issue.
How do I get the ice maker to go into a harvest?

0 votes
2k views

Has any technician worked on these! GE’s New Fridge Has a Keurig Coffee Machine Built Right …
You can complain about the quality of the coffee they produce all you want, but now that those pod-based Keurig hot beverage machines come built right in to GE’s ne…

0 votes
2k views

I was working a WPRB8050D1CC GE WASHER, Water was all over the floor, I’m pretty sure that it was a water level sensor/switch. But how do you know how much water “how many inches” the switch is set to trip at? How full is High Med Low levels? The water came up to 3/4 of the drum and I shut it off, “That seemed way high”…

0 votes
2k views

This dryer was making a loud knocking noise. I thought there was to much play in the rear bearing, so I replaced it. Front drum slides exhibited no cracks and appeared to be sound. Now it is making on intermittent hammering sound. I don’t have any more ideas and would appreciate anyone else’s. Thank you.

0 votes
3k views

Freezer evaporator frosted fan working , replaced main board told customer to leave ref off to defrost evaporator she did that. customer call back a few days latter refrigerator warm freezer was working fine. I stopped out to check freezer -2 degrees ref 60 . Freezer fan was not running compressor was running . Shut refrigerator off to check make sure compressor cycled off. when i turned tit back on evap fan started to run. customer told me she only left it off for 6 hours. Not sure if fan may have been frozen, called her back next day, my tech went back with a new board and replaced 2nd board he said the fan was running when he got there . Is there anything that would stop the evaporator fan from running. or is this one of the fans if it goes bad can take out the board fan was not replaced yet

0 votes
3k views

GE Oven Model JKP45W0W2WW Original board part #WB27K5318 changes to part #WB27T10290. The configuration of wiring the terminals is different on the new board and there was no wiring diagram in the box. Expensive board I would hate to get it wrong. Does anyone have a wiring diagram for the new board? I’m told there should have been one in the box. Most of the confusion is with the common wires. On the old board the two common wires are marked C and Com. On the new board the markings are Com0 and Com1. The configuration of the new relays is different as well but I think I have that part figured out. The reason I am changing the board is the clock went blank and is unresponsive to the touch panel. The touch panel beeps weakly when buttons are depressed. Should I be looking for a failure in the oven that caused the clock failure or do these things just go out on there own. Oven was not in use at the time of failure and no self clean was being done at the time. The customer heard the oven make some sounds and went to check it and the display had gone blank. I know this was lengthy. Thank you for any advise.

0 votes
6k views

Model – PSC23NSTDSS Serial – VL445258
Says refrigerator side getting warm 54 degrees. Freezer side running zero.
Refrigerator temperature normal. Fresh food 36 and freezer 0. . Stated Monday afternoon. Left door open for 3 minutes to see if unit goes into liner protection and freezer fan runs on high. Works fine. Confirm damper/fan assembly in refrigerator working. . Air return clear. Run diagnostics test. Only thing that didn’t pass was temperature control panel to dispenser board communication. That failed. Did try my test control panel I carry in place of customers panel. Same results. Failed. Don’t really understand why temperature control panel talks to dispenser board when there is nothing on temperature control panel that controls anything on dispenser board. Refrigerator door switch is on side wall. Confirmed door switch is being activated by door. When door is one inch from closing, switch turns off interior lights. Currently have door switch taped closed. Did go ahead and do the system reset. . Thermistors passed testing, but then again you never know. Also is the picture of thermistor old style? Should I maybe upgrade them?

0 votes
3k views

Can this part be used on the refrigerators with plastic liners. If yes, is the wiring the same as with the first models? Also, did GE produce other models with the same water line freezing problems after discovering this problem?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

This machine had some bad switches “I removed them” but it still wont start ?
Lights light makes sounds but when I push start it makes a chirp then nothing.
Is there a diagnostic mode for this machine?

0 votes
2k views

GE microwave high voltage capacitor needs replacement. It’s rated 0.91uf. Costly under GE part.
Want to use an aftermarket part. Can only find a cap rated 0.90 or 0.95uf.
Which way would you go? How will it affect output?

0 votes
2k views

GE bottom mount refrigerator section is warm freezer o.k. evap fan running damper intermittent opening. when we have it apart it opens and closes . replaced refrigerator thermistor and rear board. a head scratcher damper open when we close up ref customer calls back ref warm

0 votes
3k views

I have a General Electric microwave oven and a security code was added that we forgot, anyway to clear it ? Thanks in advance

0 votes
3k views

I NEED TO REMOVE THE BOOT HOW TO REMOVE FRONT CONTROL PANEL

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

GE gas dryer unit is shutting down mid cycle and not blowing the heat.

0 votes
2k views

One of our guys has a washer that isn’t spinning or draining. All the obvious checks were fine. One technician of ours suggested 4 new dampening straps and a coupler. Do you guys have the part information on those?

0 votes
3k views

When I opened up the evaporator cover it was clearly frosted evenly indicating it had not defrosted in a few weeks. I found a thermistor instead of a defrost terminator. I looked around for a computer board but can’t find one. Can this be a line voltage thermistor to control defrost heater? Unit has a regular timer. I can’t tell anything from the diagrams . Any help will be greatly appreciated Thanks,

0 votes
3k views

I have a GE washer stack unit the customer says that it is squeaking “squealing” she says it was intermittent but more and louder now. Thanks so much.

0 votes
2k views

Model – ZISB480DMA
Serial – GD039067
Fresh food section freezing food. When you touched the warmer key pad it would display picture.
Can somebody please explain what that means?
Problem is damper door broken off.

0 votes
2k views

I replaced the replaced motor fuse link and ran a test cycle, and operations checked out. I let the customer know that if it happened again it’d need the motor. Do you guys have pricing and availability on that just in case I need here in the near future. Would really appreciate it.

0 votes
3k views

We had a defrost problem on a refrigerator 90 days ago. WE DEFROSTED EVAPORATOR – REPLACED EVAPORATOR THERMISTER AND MOTHER BOARD . Now we went back out for a no cool, compressor was not running cycling on and off on overload. We replaced the mother board and the compressor started running perfect amperage. The only issue now is the lights in the fresh food and freezer flicker on and off every 5- seconds. We tried a second board with same symptoms. We checked all connections and harnesses including the new thermistor we replaced. We unplugged the display thinking there may be a short with no success. Has any member seen this issues or have any suggestion on a direction to move forward ? Thanks in advance. Matt

0 votes
3k views

I was going to take the latch assembly, anything else just as a precautionary measure since I haven’t got my hands on it yet?

0 votes
3k views

Trying to do a lookup and my usual sites aren’t working, need the igniter part for this unit. Current one is not lighting at all anymore. Appreciate you guys always being willing to help me out!

0 votes
3k views

My freezer drain is iced up blocked evaporator fan. I cleared ice from fan drain line that goes down throw cabinet. You can’t see drain line down by compressor compartment. The drain pan to right of compressor in back can’t see or touch drain line. any ideas how to make sure drain line open. Thanks in advance