All Answers » Re: Wont start » Comments for "Re: Wont start"
    • Guest
    • 6 years ago
    It is the complete assembly and I followed instructions explicitly. There was no mention of programming, however I will check again. Looking at tech sheet you provided in diagnositic mode test 1, 2, 5 & 7 only show “00” on each? Anything else I may test? Overlooked?
  • Is the condenser fan motor running. Or just the evaporator fan motors. It sounds like at minimum you may have a bad inverter board or a locked up compressor. However the condenser fan motor should still run. Have you tried forcing the evap fans to run in service mode?
    • Guest
    • 6 years ago
    Neither fan is running at all. I do not know how to force evap motor, any instructions? I did test compressor and it test at 6.5 ohms on all three pins (spec is 6-7 ohms)
  • All tests are on the first page of the technical diagnostic sheet link. You can test the evaporator & condenser motor for a pass or fail test. DID YOU CLICK ON THE DIAGNOSTICS LINK ? The service diagnostics mode mode is half way down the first page.
    • Guest
    • 6 years ago
    I did do a service diagnostic test the fan test show “- -“ showing the fans are on, but neither are on? I do not mean to frustrate you, I am just at a loss since I tried service diagnostics, new board and no fans or compressor? I feel I have a faulty kit or I have missed something?
  • The condenser motor is 120 volts, are you getting 120 to condenser motor ? If you are not I would go with a new board.