0 votes
186 views

Please me help

1 vote
293 views

watched your video, ordered a new capacitor and relay module. Installed new unit same issue. Any other solutions? Refrigerator is only 13 months old.

  • twobe1 asked 5 months ago
  • last active 5 months ago
0 votes
290 views

The condenser for this combo needs to be changed due to moisture not being removed. I would like to know if there are any videos for this model as its a never version. Need any tips on assembly for this part.

  • GeekJames asked 5 months ago
  • last active 5 months ago
0 votes
338 views

Washer give a cancel error on heavy bedding loads. What could be the cause of this?

  • GeekJames asked 6 months ago
  • last active 6 months ago
0 votes
464 views

How to uninstall water filter housing for this model.

  • GeekJames asked 6 months ago
  • last active 6 months ago
0 votes
453 views

I need to know how to remove the water filter housing RFID board. Board has a small bolt screw not sure what size tool needed to remove. Any videos, service manual and tools used to perform repair would be greatly appreciated.

  • GeekJames asked 6 months ago
  • last active 6 months ago
0 votes
431 views

The leak is coming from the water valve into the fridge. I tested the valve: 185 ohms. I also tested it mechanically thinking it would stay open but it didnt. Could this issue be with the ice maker or mainboard. I dont know how common this fail is with this refrigerator.

  • SiNRG asked 6 months ago
  • last active 6 months ago
0 votes
401 views

Main control board and inverter board have been replaced Polarity at plugged checked good put washer on normal cycle drain pump kicks on while sensing door does not lock and does not fill with water door lock flashes on display E91 error code

  • Loinest76 asked 9 months ago
  • last active 9 months ago
0 votes
422 views

Does this unit have a heat exchanger?

My technician said he needs this part due to a Freon restriction. We are not finding a picture on the parts diagram.

My tech said its a capillary tube running from the evaporator that is likely restricted. He was working on a sealed system repair, replacing the compressor and evaporator today.

Please let me know the part number that would be needed.

  • gregoryb7 asked 9 months ago
  • last active 9 months ago
0 votes
432 views

GE Washer fills with water and starts to turn for about 5 seconds and then stops.

  • SiNRG asked 9 months ago
  • last active 9 months ago
0 votes
400 views

In the diagnostics mode the washer in the spin test, the clutch engages ok but the motor does not work. In the agitate test the washer fills but the motor does not work.
I can hear a momentary relay on the board and the motor seems to try to energize for less than 1 second, but nothing else.

  • Pancakes asked 10 months ago
  • last active 10 months ago
0 votes
496 views

change the control board /water valve and door latch water presuer is ok but still code is on

0 votes
567 views

GE Dishwasher Model GDF530PGM0BB
stops mid cycle, all lights flashing, turning power off resets unit to normal,
run thru cycle, repeats problem

0 votes
452 views

can you guide me to locate video for Frontload Dryer to access these main control board to replace it.

1 vote
590 views

hello, Have a side by side refrigerator and the fresh food section is getting too cold. Freezer seems ok.

Showing 1 - 30 of 2k results