Answered
0
0

We had this and it working fine at one location, and now not at it’s new location in a different house. Doesn’t seem like the compressor is even running at all. I opened up the back to take a look around and there is a harness that is loose, and stretched really tight from the compressor. I reattached it firmly in place and it came back on but I’m worried it will happen again with the wires being so tight and barely fitting where they are supposed to go.

Model Number
RS25H5121
Best Answer
0
0

Arthur, we’ve only come across a couple of these, but there is a replacement harness that is about 50mm longer than the original and should be exactly what you need. The replacement part # is DA39-00154B. Be sure it doesn’t revert you back to the DA39-00154J because that is the original that you’re having an issue with being too short. Good luck!

(This also effects models: RS25H5111 & RS25H5000 in all colors)

0
0

i would just make sure connection is fully seated it should be fine

Showing 2 results
Your Answer

Please first to submit.