Hello
See technical service manual link below with complete technician diagnostics for the models listed below. You must be logged to see the manual link below. Matt Ace technician
gas18psjrss
gas18psjrww
gas18pgrss
gas18pgjrww
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for the models listed below. You must be logged to see the manual link below. Matt Ace technician
CDT835SxJ0xx
CDT865SxJ0xx
PDF820SxJ0xx
PDT825SxJ0xx
PDT845SxJ0xx
PDT846SxJ0xx
PDT855SxJ0xx
ZDT915SxJ0xx
ZDT975SxJ0xx
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for the models listed below. You must be logged to see the manual link below. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for the models listed below. You must be logged to see the manual link below. Matt Ace technician
AZ45E07DAP_1
AZ45E09DAP_1
AZ45E12DAP_1
265 VOLT MODELS
AZ45E09EAP_1
AZ45E12EAP_1
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for your model. You must be logged to see the manual link below. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for your model. You must be logged to see the manual link below. This manual covers several models. Matt Ace technician
GFWS1705H
GFWS1700H
GFWN1600J
GFWN1300J
GFWH1200H
GFWN1100H
GFW400SCK
GFW450SPK
GFW450SSK
- AV Repair Help answered 7 years ago
Hello
See technical service manual link below with complete technician diagnostics for your model. You must be logged to see the manual link below. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
See the technician links below. Have you checked your water pressure from the saddle valve to the water inlet valve. You say that so far you replaced water filter, water fill inlet valve & ice maker. Have you replaced the saddle valve ? Its very common for the saddle valve to develop lime and calcium deposits that will cause low
pressure. Matt Ace technician
- AV Repair Help answered 7 years ago
Hi. I could not find a service manual or any tech info on this unit. I did find 2 training manuals for similar units, possibly this unit. It sounds like everything is working properly and you have enough water. Make sure the dishwasher is hooked up to hot water supply. If next to a sink run the hot water at the sink first before beginning the cycle to the dishwasher gets hot water as fast as possible. The dishwasher will heat up the water but that alone is not enough.
It only heats up the water about 10 degrees or so. It has to have hot incoming water to clean properly.
- Brian, Ace Appliance answered 7 years ago
- last active 7 years ago
Hi. I have attached the tech sheets/ service manuals for both units. To determine your no heat situation you will need to take an Amp draw when the unit is running. If above 3 amps your issue is on the high voltage side, which would be your transformer, capacitor, magnetron, and diode. Most likely a bad magnetron and diode. If below 3 amps( you will usually get about 1 amp) you issue is on the low voltage side which would include your door switches and control board. IF you have 120V at the main relay on the board with the door closed it is not your door switches. If not check your door switches. Press start to turn on a cook cycle. If the 120V stays and does not drop to 0 then you have a faulty main control board. The tech sheets have flow charts you can follow to get to your faulty component as well.
- Brian, Ace Appliance answered 7 years ago
No. The moisture sensor should not stop heat. A bad moisture sensor could cause the clothes to not dry properly or an error code. The flow chart does not mention anything about the sensor for a no heat issue. If you have a time dry selected it would eliminate the sensor as a possibility since the sensor is not used in a timed dry cycle.
- Brian, Ace Appliance answered 7 years ago
Hi. I have attached the service manual for you on this unit. Page 26 has a flow chart to follow for this electric dryer not heating. This will get you to the fault. You can also run diagnostics to see what error codes you may have. Could be the control board if all other heat components check good.
- Brian, Ace Appliance answered 7 years ago
Hello
Fisher & Paykel Appliances will be introducing the new suffix letter system to the Product Code currently printed on the serial plate of products. This suffix letter will change whenever a part is changed that is not completely retro-fit without the need for a kit, or whenever a cosmetic change is made.
- AV Repair Help answered 7 years ago
Hello
The WB27X11213 is rated at 70/40 . The KSD210 I am sure is just the original thermostat. see the link below on the step by step troubleshooting guide for your unit. This will walk you through every part and tell you where to check voltage, amperage, ohm readings. this will help before you replace the thermostat to make sure you do not have any other issues that could take out the new thermostat. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
The most common causes of elements burning out is is inadequate air flow across the heater assembly. I would check the blower housing to see if it is impacted. then do A complete tear down to make sure there is no lint causing inadequate air flow. Also check the outdoor vent to make sure the it is clean and the air louvers are opening properly outside. 95% of the time this is the issue. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello see the manual link below for complete diagnostics on the Zoneline systems. It covers the models listed below
AZ90E09D_C
AZ90E12D_C
AZ90E18D_C
AZ91H09D_C
AZ91H12D_C
AZ91H18D_C
AZ91H09E_C
AZ91H12E_C
AZ91H18E_C
AZ91H18E_S
- AV Repair Help answered 7 years ago
Hello
See the complete diagnostic guide for this unit in the link below. You must be logged in to see the link. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
See the service manual link below for the Haier # HRQ16N3BGS unit. You must be logged in to see the link. Matt Ace technician
- AV Repair Help answered 7 years ago
Hello
See the complete diagnostic service manual link below. You must be logged in to see the manual link. Matt Ace technician
- AV Repair Help answered 7 years ago
Some 10 and 12 cu ft. refrigerators may experience insufficient cooling and an
excessive amount of frost on the evaporator and evaporator cover.Models affected:
GTR10GBEBWW
GTR12GBEBWW
GTL12GBEBBS
- AV Repair Help answered 7 years ago