Hi. I have attached the service manual on this unit for you. It does not get into details about the sealed system of the unit. Was the condition of the unit the same before and after replacing the compressor? Did it have refrigerant in the system before you replaced the compressor? Also, did you install a filter drier or have a high side access valve/ port? Does the compressor run? If so, what are your low and high side pressures? You should roughly have 0-15 psi low side pressure and 130-180 high side pressure with the compressor running.
- Brian, Ace Appliance answered 8 years ago
Hi. I have attached a video for you on how to enter the program code. I hope this helps. It is on a similar model. Start at 5:00 mins on the video.
- Brian, Ace Appliance answered 8 years ago
Hello
It sounds like your entering in the wrong programing code. The Program Code is located on the Serial Plate on this unit after the word Code. If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program …CODE of PE0000 will show ).Once the correct Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated.
The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes.
Control board Troubleshooting
Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
1. Press and hold the Door Alarm Keypad.
2. Press and hold Freezer Temperature DOWN /- Keypad within 3 seconds.
3. Release the Door Alarm Keypad and wait 3 seconds.
4. The control will display PE to indicate the programming mode.
5. Entry is confirmed by pressing the Freezer Temperature DOWN /- Keypad once more.
6. The control will display the current Program CODE. This value should be validated with theProgram CODE printed on the unit serial plate.
NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.
7. Press the Refrigerator Temperature UP /+ Keypad or Refrigerator Temperature DOWN /- Keypad to change the digit value with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature UP /+ Keypad to select the next digit.
9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN /- Keypad until the Program CODE begins flashing
indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program
CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this
process should be repeated.
The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes.
Service Test Mode:
The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode by performing the following sequence
of events:
1. Press and hold the Door Alarm Keypad.
2. Press and hold Refrigerator Temperature UP / + Keypad.
3. Release the Door Alarm Keypad and wait 3 seconds.
4. The Freezer display will display SE confirming entry in the Service Mode.
5. Press the Refrigerator Temperature UP /+ Keypad again to confirm entry in the Service Mode.
6. Display will show 101 in left display and numeric or dashes in right display.
7. Press Freezer Refrigerator Temperature UP / + Keypad and Freezer DOWN /- Keypad to toggle through Service Test numbers.
8. To exit service test mode, open and close refrigerator door or hold door alarm for 3 seconds
- AV Repair Help answered 8 years ago
Hello
Is the unit cooling ? Or do you have just a light issue ? You will need to enter the unit into the diagniostic mode by the steps below. Then you can check many of the controls and switches. Click on the diagnostic manual link below and go to page #52 for further steps. Matt Ace Technician
Diagnostic Mode
The steps required to enter Diagnostic mode are:
1.) Adjust the temperature setting to “0°F” using the UP ARROW and DOWN
ARROW buttons.
2.) Press and hold both UP ARROW and DOWN ARROW buttons simultaneously
for 10 the UI beeps and display “88”, indicating the system has entered
diagnostic mode.
To exit diagnostic mode, press and hold the UP ARROW and DOWN ARROW buttons
until the UI beeps. The display should display the interior temperature indicating the
system is no longer in diagnostic mode.
- AV Repair Help answered 8 years ago
- last active 8 years ago
Hello
Go to the service manual link below and go to page #23 for troubleshooting & diagnostics. There are many possibilities for your refrigerator not cooling. The Reversing Valve AJU34510512 you installed monitors the refrigerant flow to both evaporators only. Matt Ace technician
- AV Repair Help answered 8 years ago
Hello
I have looked up every service bulliten that can be related to your issue. See links below ….Matt Ace technician
- AV Repair Help answered 8 years ago
Hello
I have provided thetechnician diagnostic sheet below. Do you have any display error codes ? From what I can see without the running though diagnostics it may be a Display board touch pad #154734601. Run throgh all the tests in the service manual below to be sure. Matt Ace technician
The water/service test is a special function initiated from the power failure mode or idle
mode.
While in power failure or idle mode – simultaneously press the DRY/AIR DRY and
START/CANCEL pads for 3 seconds.
The dishwasher will then step through the test cycle per the chart.
Pushing the START/CANCEL pad will advance the dishwasher to the
next step.
or LO..Low liquid in the rinse aid dispenser
CL ……….Close and latch the door
ER/ER….Switch Failure
PF- …A power failure has occurred
ER/CE….Configuration Error
ER/uo…..Vent will not close
ER/uF…..Fan not running
- AV Repair Help answered 8 years ago
Hello
See the diagnostic sheet link below for your model. Matt Ace technician
- AV Repair Help answered 8 years ago
Hello
See complete technician diagnostics guide in the link below. the 13E error is ( Humidity-Sensor Error ) to troubleshoot sensor , measure the voltage between the Main PCB CN30 12PIN – 7PIN, it should read between 4.5V~1.0V. The 26E error is ( Ice Maker Function Error ) This error will occur when the Freezer Ice Maker error occurs more than 3 times, the error will be displayed. See complete diagnostics on page #49 in the link below. Matt Ace technician
- AV Repair Help answered 8 years ago
Hi. I have attached the job aid for this oven/microwave. On page 24-4, it has detailed instruction on how to replace the turntable motor. Good luck with your repair.
- Brian, Ace Appliance answered 8 years ago
- last active 8 years ago
Todd
See complete diagnostics below for SUD Error. There is not an A44 error code for this model. If the pump will engage and not pump I would test the pump on 5-4 in the job aid link below. It sounds like a bad pump if you have power and its pumping. Verify with disgnostics liks below. Matt Ace technician
Possible causes for a ( SUD ) Error :
If too much detergent was used:
– Run the unit through a Rinse/Spin cycle.
– Run a Normal cycle without adding any detergent.
This should clear the unit of the excess detergent.
1. Check the drain hose and make sure it is not plugged or kinked.
2. Unplug washer or disconnect power.
3. Check wire harness connections to the drain pump, pressure switch, and Central
Control Unit (CCU).
4. Check/clean drain pump filter of foreign objects.
5. Plug in washer or reconnect power.
6. Check drain pump.
7. Check the pressure switch.
8. Verify CCU operation by running a Diagnostic test or any cycle.
- AV Repair Help answered 8 years ago
Hello
The easiest way to verify your issue is to follow the flow chart on page #26 in the service manual link below. It will take you step by step. Matt Ace technician
- AV Repair Help answered 8 years ago
Hello
I have found an updated cam kit for model see link below. Also there is an updated hinge kit for model VCSB482 and you have a VCSB483 . See the links below. We have also found on these models if the drain is plugged it will prevent the vapor seal from working. Make sure the drain is open so air can be released through the drain trap when the door is shut. This is common on the Viking & Sub-Zero models. These doors have issues due to the extreme weight of the doors along with custumers overloading them. Hope this helps . Matt Ace technician
- AV Repair Help answered 8 years ago
Hello
The refrigerator thermistor is located near the light bulb housing assembly.
If the refrigerator is getting too cold and freezing food please look at the service bulliten liks below. Also run the unit through diagnostics before replacing the thermistor.
If the ice maker is not connected to water, the ice maker must be shut off. Failure to do so
may cause food in the refrigerator compartment to freeze. In certain conditions, air leakage from the ice maker compartment may cause foods in the refrigerator section to freezer, refrigerator Temperature too cold.
Order Ice Bin Cover Assembly and Air Damper Seal Service Kit, Part # W10295078. Follow the
instructions supplied with the kit to install.
Matt Ace technician