0 votes

Good question – I have gone ahead and linked a video below that may assist you

0 votes

We have an video that could help you. Check out the link below.

0 votes

Hello
If you cannot get the unit into the diagnostic mode fro the instructions on page #3 of the technician sheet link below. Your only option is to replaced the board as it should always go into diagnostics. I would disconnect power for 5-minutes to reset the board and try one last time before replacing the board. See related video links below Matt Ace technician

0 votes

We have an video that could help you. Check out the link below.

0 votes

Hello
Here is the diagnostic sheet.

Matt Ace technician

0 votes

Hello
See provided information available for the model. Matt Ace technician

0 votes

Hello
See technician link below. Matt Ace technician

0 votes

Hello
See requested information link below. Matt Ace technician

0 votes

Hello
See link below for the technician sheet. Matt Ace technician

0 votes
In reply to: COOLING CYCLE

Hello
See diagnostics and repair guide .

Matt Ace technician

0 votes

Hello
Yes, there is a fix for the old plastic tab nut. The new part number kit is DC82-0197X . You will need to have your own lock tight, it does not come with the kit and you definitely need it. See video link below for help . Make sure you put the unit not service mode first , then test mode . This is important to get right because during a normal repair tech MUST use service mode before test mode to avoid deleting saved error codes. Matt Ace technician .

1 vote

Hello
See wiring diagram and service diagnostic sheet for your model. The elements and relays are controlled by the board. Matt Ace technician

0 votes

Hello
There is an upgrade kit for this model. See video link below for the S-Hook ( Bush pin ) & bracket upgrade . Part # DC82-01097W KIT . DC82-01097W

0 votes
In reply to: burners will not light

Hello
See the service manual for your model. It sounds like you may have a defective spark module. #74004283 . Matt Ace technician

0 votes

Hello
There is no service bulletins on this model. Is the evaporator completely frosted at a -20 degree coil temperature ? If not this could be a start of a sealed system issue. Is the dispenser ice flap closing 100% of the way ? Is the evaporator fan motor running at the correct speed ? Are your door seals good or is there any shelf or food preventing the doors from closing all of the way ? You could have a damper door issue or thermister not sensing the proper FF temperature. Last is main PCB not functioning properly. I would check all of these issues , then start replacing the lowest price parts after completing the diagnostics.

0 votes

We have an video that could help you. Check out the link below.

0 votes

Good question – I have gone ahead and linked a video below that may assist you

0 votes
In reply to: Drum is not spinning

Good question – I have gone ahead and linked a video below that may assist you

0 votes

Thanks for asking a question. I looked up that model number and we have a video on a similar issue. I put a link below the answer.

0 votes
In reply to: Not keeping cold

We have a video that steps you through this very issue. View the video linked below

Showing 6241 - 6260 of 10k results