I recommend replacing the control board on this unit. We done 14 control boards on this exact unit with the same symptoms.
- AV Repair Help answered 10 years ago
- last active 10 years ago
You need to replace the rear drum supports on this unit. That will correct your issue. See parts and video links below.
- AV Repair Help answered 10 years ago
- last active 10 years ago
You have a frozen condensate drain. I recommend clearing the ice from the drain line on this unit. You may have a food wrapper stuck in the drain.
- AV Repair Help answered 10 years ago
- last active 10 years ago
I recommend replacing the bake igniter on this unit. That is the most common issue . See parts and video links below.
- AV Repair Help answered 10 years ago
- last active 10 years ago
I recommend replacing the drain pump on this unit.See parts and video links below.
- AV Repair Help answered 10 years ago
i recommend replacing the dispenser switch bracket on the ice maker.See parts and video links below.
- AV Repair Help answered 10 years ago
I recommend replacing the ice maker on this unit. See parts and video links below.
- AV Repair Help answered 10 years ago
I recommend checking to see if there is any debris in the drain pump and if there is remove it then try to run the unit again.
- AV Repair Help answered 10 years ago
I recommend replacing the pump on this unit.See parts and video links below.
- AV Repair Help answered 10 years ago
You most likely have a shorted out burner on this unit.I recommend replacing the burner.
- AV Repair Help answered 10 years ago
i recommend replacing the clutch and clip on this unit.See part link below
- AV Repair Help answered 10 years ago
I recommend installing a new control board on this unit.See parts and video links below.
- AV Repair Help answered 10 years ago
I have found that when experiencing this problem on this unit it is often due to the knockout plug in the disposal not being removed. I recommend checking to see if the knockout has not been removed from the disposal.
- AV Repair Help answered 10 years ago
Hey Todd,
I have seen this issue many times before. Sounds like a sealed system issue. The unit could be leaking Freon. It runs constantly and can somewhat maintain the refrigerator temps, but it can just not produce cold enough temps to keep freezer temps. With it running non stop it is freezing some food in the refrigerator.
- Brian, Ace Appliance answered 10 years ago
HI. I am having a hard time finding any information on this unit. Do you have the tech sheet? What does the F1 error code refer to? What does the ice maker do? Does run any water? make any ice? I have attached a link to our ice maker repair videos.
- Brian, Ace Appliance answered 10 years ago
HI. The ER error code looks to be related to the evaporator fan motor. Get into the freezer and remove the back panel to check the evaporator fan motor. You could have a bad fan motor or you might not be getting power sent to the fan motor. With the fan motor not running it will cause warm temps in both sections. This would cause the ice maker to stop working as well. I have attached the tech sheet for you also. I have attached a video for replacing the fan motor.
- Brian, Ace Appliance answered 10 years ago
There is not a way to verify that a new board is good or not. AS far as testing and diagnosing a control board in a unit goes, the best test is power in and power out. At the J1 connector at the board. You are checking from line to ground at black and green. Check from black to light blue which is pin 1 and 3. This is line and neutral. You should get 120v. If not your loosing a neutral somewhere. Go back to the outlet and check to see if you have proper voltage. line to neutral and line to ground should be 120v. neutral to ground should be 0v . There is a diagnostic mode on the tech sheet, but I most likely will not work with the unit not powering up. The unit should start up after plugging the unit back in after the repair. I have seen any communication errors on these units that usually result in the main board being the fault. Its a communication error between the UI board and main board. Above I have attached the tech sheet previously if you need to take a look at it. IF the inverter board is bad it should not cause everything to shut down. Power piggy backs off of the inverter board to the main board so it should not make a difference. Going back to the main board you installed. I show that is not the correct part number you installed. The main board on the bottom of the unit is 241996361. You may have installed the wrong board. The part number you are providing is coming back as invalid. not even listed as a part. I have installed this board before and pinched a wire which shorted out and caused the new board to go bad. IF you had a power surge to this unit it could have also taken out multiple boards. I dont think extending your time will be an issue. I will check with my manager.
- Brian, Ace Appliance answered 10 years ago
I recommend replacing the idler bracket on this unit. See parts and video links below.
- AV Repair Help answered 10 years ago
I recommend replacing the bake ignitor on this unit.See parts and video links below.
- AV Repair Help answered 10 years ago
This unit needs a new main control board in my opinion with the symptom you are having. With your model number we have replaced several boards that have corrected the issue.
- AV Repair Help answered 10 years ago
- last active 10 years ago