0 votes
In reply to: forced harvest

Hi. I have attached the tech sheet for you. Take a look at test 44 to run the ice maker.

0 votes

Hello
See the #37 page technician diagnostic manual link below. Are you getting any error codes ? We have had several of these units RPS and rotor issues. There are no service bulletins currently on this product.

0 votes

Hello
See the complete diagnostic link below.
To reset the CSM. (GE Technicians use Laptop Diagnostics Program)
Entering Service Mode will reset the CSM.
To enter Service Mode:
1. First enter Consumer Error mode as directed previously. After the ten (10) second door check
has completed, continue to next step.
2. Enter Service mode (while in Consumer Error Mode), by pressing and holding the Select Cycle
button for five (5) seconds.
Fill, circulate, heater and drain tests can be selected by using the Select Cycle button. To start each
test, press the Start button.

0 votes
In reply to: MAIN BOARD

Hello
We have not had to replace both boards for this issue before. I would start with the main board only. See the schematic diagram link below.

0 votes

Hello
See video links to a model close to yours #WA456DRHDSU . Also see your exact service manual with instructions and breakdowns for the boot replacement. Matt Ace technician

0 votes

Hello

         See information links below. Matt Ace technician 
0 votes

Hello
See technician diagnostics guide link below. Troubleshooting starts in section #8. Matt Ace technician

0 votes

Hello
Go to the Job Aid link below ans component access is in section 4-1. Matt Ace technician

0 votes

Hello
See the Fast track diagnostics troubleshooting guide link below. I will have more details on answer after consulting another technician.

0 votes

Hello

  See the complete diagnostic Aid diagnostics. We have seen the diverter valve defective internally only once out of hundreds of these serviced. You can change the coil on the valve also, i would try that first. We have found these models more commonly with evaporator refrigerant leaks. 
0 votes

Hello
Can you double check your model number #KF1S29PBMS01. This is not a correct model number. Matt Ace technician

0 votes
In reply to: no hot water

Hello
See possible issues below with service manual links.

  • Are hot and cold inlet hoses reversed?
  • Both hoses must be attached to both washer and faucet, and have both hot and cold flowing to the inlet valve.
  • Check that inlet valve screens are not clogged.
  • Remove any kinks in hoses.
  • The energy star washers use cooler wash and rinse water temperatures than your previous washer.
    This includes cooler hot and warm washes.
0 votes

Hello
See the 80 page diagnostics and troubleshooting guide link below for your model. We do not have access to the complete parts diagram. You may find that at Sears parts direct website. See link below to your model https://www.searspartsdirect.com/model-number/t24ir70nsp02/1085/0167100.html

0 votes
In reply to: ERROR CODE

Hello

        The F1 - E5 error is the inverter error. See the complete Job Aid manual and technician sheet. I will consult with other technicians on other possibilities and get back to you later today. 

PROCEDURE: on inverter diagnostics , perform steps 1 through 3 of “To
Enter Diagnostics Mode.”
1. Unplug microwave oven or disconnect power.
2. Replace microwave oven inverter.
3. Replace all parts and panels before operating.
4. Plug in microwave oven or reconnect power.
5. Verify operation is normal. Go to Step 1 of “To Enter Diagnostic
Mode” and complete checks.

0 votes
In reply to: WASHER STOPS

Hi. Sounds you have a faulty pressure switch or control. Make sure there are no holes in the pressure tube. Make sure the drain hose is properly installed and elevated. Make sure the drain ia not causing a siphon. If everything is good i would try replacing the pressure sensor first and then the control. I have attached the tech sheet for you. Try running the auto test mode as well.

0 votes
In reply to: Service manual

Hello
See technician sheet link.

0 votes

Hi. Try pressing power freeze and power cool at the same time and hold for 10 seconds. This should clear out the 88 display. It is not an error code. When power is interrupted the 88 will show on the display until reset. I have attached the service manual for this unit.

0 votes
In reply to: ice maker removal

Hello
See the video on a model close to yours and exact instructions in the technician sheet link below. Matt Ace technician

0 votes
In reply to: Gas range shuts off

Hello
Was it doing this before you replaced the spark module ? Did you verify it is the correct part number WPW10331686 ? Did you follow the instructions in the parts box ? On this spark module with serial numbers between RK33- Rx42 the red wire needs to be removed and taped off the old board. See link below for instructions and technician sheet Matt Ace technician

https://partsdr.com/part/w10331686-spark-module-control-board?gclid=EAIaIQobChMIuJuD5N6u4QIV1B-tBh0ljQAWEAQYBCABEgKdIPD_BwE

0 votes

Hello
See manual link below. The ( Door won’t ) unlock diagnostics are on page #11. This will give you step by step diagnostics and troubleshooting. Matt Ace technician