Hello
We use A PRO-Charge Freon Refrigerant Scale when charging to dial in the exact amount of refrigerant recommended by the factory nameplate. We also make sure we bleed the refrigerant of air before charging and and evacuate the system. We have charged and replaced over 1000 compressors and evaporators. We were trained by Whirlpool factory trainers to charge liquid on the low / suction side. We have NEVER had any issues charging this way . I believe your issues or secondary problem are a plugged braze on refrigerant line or filter dryer . You need to go back and evaluate the unit by putting g the gauges on to check your pressures. See video link below. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
If you replaced the defrost heater, thermostat, and main control board. I suggest you replace the two temperature sensors part numbers below. If a sensor is defective it will cause Ice/ Frost build up on the coil. If you replaced the sensors and still have an issue replace the main control board. We have had a few new bad control boards out of the box. Matt Ace technician
WR50X10027, WR50X10034
- AV Repair Help answered 10 years ago
Brain
Here are the technical information sheets we have available. I also included a video on a PFS22 series refrigerator. Hope all is well on your end .Matt
- AV Repair Help answered 10 years ago
This is the closest manual I have to your product sorry. There should be a diagnostic manual with your product. Did you check in the unit ?
- AV Repair Help answered 10 years ago
Hello
If you ran it through diagnostics and it is not cooling you should have error codes. These error codes will give you the specific direction to go it for the repair. Without error codes we are just guessing.
E01 RC sensor value is outside the defined range
E02 FC sensor value is outside the defined range
E03 TCD senor value is outside the defined range
E15 Ambient sensor value is outside the defined range
E10 CM Eeprom
E11 DOM Eeprom
E20 Communication error between CM and DOM
E21 Communication error between DOM and IWD
- AV Repair Help answered 10 years ago
Hello
Is it not cooling in the refrigerator and freezer ? Is it partially cooling at all in either section ? Is the compressor running? Have you looked at the evaporator frost pattern ? Is the evaporator fan motor running ? When you say not cooling there are too many variables. You need to give us specifics otherwise we are just guessing . You have two boards in the unit 1) Power Supply Board ) Main control board. If you have lights on in the unit that is a good indication your power supply board is functioning properly. You will need to run the unit through diagnostics to verify the proper diagnoses.
- AV Repair Help answered 10 years ago
Hello
See technician link and video link below. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
We do not have much on this specific model. I have provided a service manual on the (PSD) series unit. Its not exact but it is the only information we have currently. Matt Ace technician
- AV Repair Help answered 10 years ago
- last active 10 years ago
Hello
What issue do you have with the unit ? Go through the diagnostics below and you will get the proper error code to pinpoint your issue. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
We do not have a video on this model. I do have a service manual link below with information that will help. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See technician diagnostics below in the links. Look at the service bulletin on this unit link below. This sounds like a possible sealed system issue. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
Is your compressor running ? If not you need to look at the evaporator for an even frost pattern. That will tell you if you have a sealed system problem or a possible defrost issue. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
It sounds like you may have control board issue. See diagnostic sheet below. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See diagnostic manual for your model below. Go to page #31 for diagnostics. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
We have some Wolf information but are limited. See information links below. I hope this helps Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See link below for error codes on page #37 . Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See links below for everything you requested. See test #4 on technician sheet to put diverter valve in home position. Matt Ace technician
- AV Repair Help answered 10 years ago
- last active 10 years ago
Hello
Here is the service manual and technician diagnostics link below. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See complete error codes and diagnostic guide links below. This should walk you through step by step diagnostics. Let us know if you have any issues. Matt Ace technician
- AV Repair Help answered 10 years ago
Hello
See manual link below there is a troubleshooting guide starting on page #33 . If the inverter board is blinking its detecting a motor current voltage error. The cause cold be : 1) A bad condenser fan motor . 2) Locked up compressor . 3) Defective inverter board. You can purchase the inverter board and condenser motor at Repairclinic.com and buy it to try it for up to 1-year return policy. If you can OHM out the condenser motor you can eliminate that , if not get both parts and if they do not fix the issue you have a defective compressor. Matt Ace technician
- AV Repair Help answered 10 years ago