0 votes
3k views

Dishwasher motor doen’t run, Drain works when you it cancel. Unit won’t go into diagnostics. Is there a video that shows you how. I tried any key 3 consecutive times within 1 sec. closed the door. won’t go into diagnostics. Does the tubulity sensor have anything to do with motor running? I’m sure if i’m doing it right to put to diagnostics. They say it has to be in stand by mode. Is stand by mode the pause button or is it with the door open and the start button pushed. It would be really helpfull if they have video on how to put into diagnostics.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

The problem is that someone changed the front left burner (3 stage) and they put the wires in the wrong order. I have a new burner and I would like to know which color wire attaches to which pin on the burner, the colors are Orange, Blue and Grey., and there are 3 pins on the burner. I am concerned with attempting to go on a peck and find method in case it damages the new burner.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I posted a question about a week ago and I checked the refrigerator drain and pan and they are clear and the water tank also. The water is coming from the refrigerator room at the bottom on the left side where there is a vent and damper control. Where does the air supply come from for that vent? I am not talking about the vent in the back. near the water tank where the fixer box and fan is in the rear. The water under the drawer comes from that front vent. The customer says it is often iced up.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

I DON’T HAVE ANY TECH SHEETS ON THIS UNIT, SO I COULD USE WHAT EVER YOU CAN DIG UP. THE CONDENSATE FAN IS WORKING AND THE UNIT IS COOLING WITH AN EVEN FROST PATTERN ON THE EVAP COIL. I DON’T KNOW WHERE TO START TRYING TO FIND THE FEED TO THE FAN.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

The washer won’t spin at all when ran through the cycle. Only if some water is allowed to drain and then the washer is stopped and started again, it will spin. Or if the washer is pumping but not spinning and the agitate/spin speed knob is turned from fast/fast to slow/slow the basket will start to spin. We have changed the transmission, clutch , and coupling and still no luck. I can look under and see that the clutch is not spinning at all except for when the water is drained first, so the clutch is not slipping. Would this be the motor or the spin speed selector, or timer?

1 vote
3k views

THIS A DUAL EVAP COIL UNIT. I UNPLUGGED THE UNIT AFTER 8 SECONDS TO PUT REVERSING VALVE IN THE “HOME” POSITION. I WEIGHED IN THE REFRIGERANT. PRESSURES ARE 20 LBS SUCTION AND 125 ON THE HIGH SIDE, WITH NO COOLING.
I DON’T HAVE ANY PAPEWORK ON THIS UNIT, SO I’M NOT SURE THAT THIS WAS THE CORRECT PROCEDURE RE; THE REVERSING VALVE.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

making noise when running?

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

the machine will not agitate and won’t spin.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I HAVE TWO, OF THESE UNITS, WITH SEALED SYSTEM PROBLEMS. PREVIOUS TECHS CUT NUMEROUS REFRIGERATION LINES. I NEED INFO ON PUTTING UNITS INTO DIAGNOSTIC MODE, SPECIFICALLY IN PREPARATION TO FINDING LEAK OR LEAKS AND RECHARGING. I NEED TO GET THE REVERSING VALVE IN THE CORRECT POSITION, ETC

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

The compressor is running and pulling 1 amp. the condensing coil is clean and both fans are running. I installed a service valve, on the suction line, at the compressor. when i attached the gauges it immediately went to 29 inches of vacuum. I unplugged the unit and it stayed at the same value. in your opinion what does this indicate. i’m waiting on r134a to be delivered so I haven’t tried adding any refrigerant to this point.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I had a customer with a Kenmore standup freezer and not getting enough cold on both food compartment and the freezer. We just replaced the control board and still having the same issue.
Your help is very critical. please assist.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
20k views

Top freezer working fine. Bottom fridge is too warm. Watched your video, took apart top panel, evaporator fan motor not working. dial switch in fridge makes no difference. I tested wires to evaporator motor fan, not getting any voltage to fan motor? The fridge has the dial switch that says “coldest to lowest”. took that panel down, it has the thermostat dial switch, and there is a white square thing with wiring harness connected to it next to the dial switch.
What would be stopping power from reaching the evaporator fan motor? FYI, this all happened after a power pole was hit in neighborhood, causing outage/spike. The condensor and it’s fan is running fine, freezer is working fine. Just not the fridge.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

why is this unit not making ice cubes

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

got a combo Kenmore washer/dryer, there is a11/2inch gap between the washing basket and the body at the top causing articles to full into the washer and mess up the drive belt and speed sensor, the real question is where does the speed sensor and bracket attach and secondly if there should be a gap at the top.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

i changed the air damper and it still will not blow cold air to the fridge but when i open the freezer door i will get cold air in the fridge true the damper.
also there is alot of frost around the ice maker machine

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

I was recharging the compressor with refrigerant and the compressor was hot but during recharging the compressor just shut down.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

The cild air Only flow into the refrigerator through the damper when the freezer door is open when I close the freezer door and put my hand in the refrigerator near the damper there was no air flowing

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
12k views

so i checked up what the blinking light read and it came to F5E3
hoe ever the unit did run once and then it stopped i can hear the drum trying to turn and then shots off can it have to do with the timer as well?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Ice up on evaporator, refrigerator not getting cold.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

so the freezer is working good however there is lots of frost on the front of the machine like on the ice maker cover and the bottom and also on the ice maker dispenser
also the fridge is warm not cooling good

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

what dose it mean and how can we fix it

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

so i put in into diagnostics mode and i got an error of F6 E1
how can i repair this?
its a Kenmore washer

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views
  I went out on service call on a Kenmore bottom freezer/refrigerator. I would like to know how to get the pcb in diagnosis mode. Thanks
0 votes
3k views

washer has the F25 error code stored 3 times & F17 store once.

History, the MCU was replaced. Customer ran 2 loads fine and now error codes back. I watched it run a complete cycle with large load of towels yesterday, no issues. This AM, the F17 code came back, customer left it right where it stopped. Load of towels drained but not spun out.

Problem is the tech sheet in washer has no F17 error code. Looking around online, someone suggested the user interface. I am loosing my sanity on ordering these parts and then wait and see if that was the fix!

ALL connections checked, wires ohmed, tach on motor ohms correctly, drains fine, pressure hose clear, no suds. Here this AM watching it again and working fine.

Anyone else come across this F17 code?

1 vote
3k views

I do get water through the door however ice or crushed ice will not dispense through the door I do not hear the flap opening either I try to turn the auger motor by hand and it does turn.
And the Machine is making ice

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

We are working on a Kenmore (standard Whirlpool design) SXS
Model 106.57032601 with dispenser. Ice bucket is mounted on door.
Flapper door is shutting properly and sealing. Motor is working to drive cubes. 3X
in 4 months have found ice clog inside the ice chopper mechanism. We clear it and
it works great for about 2 months then plugs again. Ice looks partially fused by
melting. Auger motor then sounds stripped when clogged but works okay when
jam is cleared.
Does that auger motor sound stripped when jammed then work when not?
Do you think the flapper is sticking open and which of the flapper doors parts would be suspect?

Thanks in advance

0 votes
3k views

Model – 253.54373300 built by Frigidaire

Looking at parts breakdown, I see there is a refrigerator damper assy ( 241600902). Wiring diagram at Sears web site is too small to read.
Does the defrost temperature control ( 5303918476 ) activate damper assy.? Looks like thermostat control is old style with a capillary tubing.

0 votes
2k views

it will agitate but will only spin if i start turning it by hand

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

i need to change the condenser and dryer on this unit. any links i can look up for info?

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views
f11

I’ve changed the MCU in CCU and I am still getting the f11 error I do not see or hear the motor or the tub turning

  • Guest asked 9 years ago
  • last active 9 years ago