0 votes
10k views

Hi – I really appreciate your videos.

I have the issue captioned above and it is just like the problem experienced in your video:

I have checked belt slippage/alignment and the belt switch (as was the problem above) and they both appear fine.

Any suggestions on what I should do next? BTW, I don’t have a multimeter so testing and diagnostics are as not easy as they could be.

  • Bret asked 10 years ago
  • last active 7 years ago
0 votes
3k views

Good day My Name is Roland. We are working on a dryer LG and need some help.
The unit will not heat well, we change the gas valve, the pilot valve comes on, but will not start full heat. The drum still rotates and we are getting no error codes. Do you have access to a wiring diagram for this unit or suggestions as to what is going on. Your help is appreciated.
Roland

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

igniter working, flame working then going out after few minutes. put in new coils, still same problem! is there a way to check the valve itself? or could it be the heat sensor? thanks
what would next step be? thanks

  • Stanya asked 10 years ago
  • last active 10 years ago
0 votes
12k views

I have examined the heating element of this Samsung dryer; but it did not appear broken. The coils were a bit black in some places but nothing broken. The inside of the dryer was filthy with lint … on the motor, in the heating element, and clogged in the lint exhaust hose. The tub spins and it has power. Is this low heat condition and indication that the heating element is going out or is there a problem with a thermostat not working correctly? What would cause a low heat condition in the dryer?

Thanks-

Fred / Lubbock, TX.

  • Fred asked 10 years ago
  • last active 10 years ago
0 votes
2k views

Gas dryer igniter will glow for about 8-10 seconds the click and will not light. Could not find anywhere what the resistance should be on the igniter. Any suggestions on what else could cause this?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
7k views

I have a customer that wants me to convert his LG dryer to LP. It is an LG model # DLG3171. I typed this number into your model # guide, with no results. I checked PartsPro website and that number came up. So I know that it is a good number. Do you have a video for this model # or something close to it showing how to take it apart? And 2, how long should a job like this take?
Thank you
Bob

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

I seem to be missing something because the coils, igniter, thermostat, and fuse are all fine. What else is there that might have failed? Need this working.

  • Evan B asked 10 years ago
  • last active 10 years ago
0 votes
2k views

dryer not heating , changed thermal fuse DC47-00016A worked hour later customer called no working agian .

  • Guest asked 7 years ago
  • last active 7 years ago
0 votes
4k views

I have a code 09 when I run the diagnostics from the panel. My dryer will beep 3 three times when after pressing power and then pressing the start button. The drum light is not lit but tested good. I’m thinking it’s the door switch, correct?

Thank you!

  • Terry Bentley asked 10 years ago
  • last active 10 years ago
0 votes
3k views

Last night, out dryer got extremely hot but wasn’t spinning. It literally took about 2 hours for the dryer to cool off, and by that I mean the door and everything. When I plug it in, you can hear the heating element(maybe?) making a soft buzz and it heats up bu the motor isn’t working.

  • David asked 10 years ago
  • last active 10 years ago
0 votes
2k views

My customer had an electrician look at her dryer. I’m guessing that he did a continuity test. And removed the “part” that sits on the side of the exhaust line. And he never came back to fix it. Well, that’s the story that I was told.
There are two wires and a little hole in the can that is about half way in back of the exhaust line. I checked out several websites, and I didn’t find a hole or a part that goes in the middle of the exhaust line. One person said that it is the drum outlet bias thermostat. But it looks like it’s located at the front of the dryer.
If you can shed any light on the subject I would greatly appreciate it. If I order that $64.00 part and it’s not the right part. Besides being stupid, I’d look stupid.
Thanks?

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
3k views

So my dryer was making noises and it was the top stabilizer so I changed it I put it back together and now everytime I start it it will shut down exactly 1.5 minutes everytime I can start it right after again and it dose it again right on 1.5 I can even time it haha so my qustion is what its my problem oh and I can run it on fluff moad for as long as it can go and it wont shut off thanks for your time

  • makita asked 10 years ago
  • last active 10 years ago
0 votes
3k views

dryer sometimes runs 10 minutes or less and f 40 error code comes up. checked harness and connections all look good

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

No heat.

0 votes
3k views

Leaking water.

0 votes
2k views

Replace therm switch dryer was tumbling but now when I push to start the dryer starts and stops and start and control light flashes and have no codes checked everything what else is there to do .I try reset and retrieve codes and get nothing whats your guess

  • Lorenzo Davis asked 10 years ago
  • last active 10 years ago
0 votes
3k views

I checked the venting, element and thermal fuse per some other threads I found on here. Still won’t work right. What else can I look for?

  • charlie asked 10 years ago
  • last active 10 years ago
0 votes
2k views

my LG dryer is not heating properly. Do you have any suggestions to resolve this issue?

0 votes
3k views

THE CUSTOMER IS TELLING ME THAT THERE IS HEAT, BUT THE DRYING IS TAKING TOO LONG. I DID NOT GO TO SEE IT YET, COULD SOMEONE WALK ME THROUGH THE DIAGNOSIS? THANK, TODD FROM NY.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

So I changed the coils and the igniter and the senser.
The falme still will go on for 5 to ten seconds and then go off.
And will repeat about 1 minute later
I have have taken the vent off of the back and no difference

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
3k views

My GE dryer smells like gas.

0 votes
2k views

My GE dryer is not level.

0 votes
3k views

Timer will not advance, Over heats, No heat at all.

0 votes
2k views

stops in the middle of the heating cycle

  • John Herrera asked 10 years ago
  • last active 10 years ago
0 votes
3k views

I am working on a Kenmore HE3. I have replaced the coils and the ( cycling thermostat ). And the burner continues to run for about 10-12 seconds then shuts off. After a few minutes, the igniter comes on, the gas valve opens up and the burner starts and run for 10 seconds or so, then shuts off, and the cycle continues.
I think it’s the gas valve, but before my customer spends that kind of money. I want a second opinion. What do you think, and why?

Bob
I would appreciate a quick call if possible. 609-437-7436
Robertdennis3382@yahoo.com

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

We’ve been out 3x now and customer is beyond frustrated. We have changed the heating element and the thermostat separate calls. Both times machine tested and cleared as working but when the customer put it in use, no heat.

  • MRAFRED asked 7 years ago
  • last active 7 years ago
0 votes
2k views

HI,
How do i get the front panel off of this dryer?

Thank you,

Mike

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
3k views
  • Guest asked 10 years ago
  • last active 10 years ago
Showing 1 - 30 of 1k results