1 vote
2k views

THE UNIT SHUTS OFF AT ABOUT 30 DEGREE F. THE T-STAT IS A DISCONTINUED PART. I HAVE OTHER T-STATS BUT I WAS LOOKING FOR THE WIRING DIAGRAM SO I CAN FIGURE OUT IF ONE OF THESE OTHERS WILL WORK. THE T-STAT HAS 3 WIRES AND A GROUND. I’M THINKING ONE WIRE IS ASSOCIATED WITH THE DEFROST CYCLE? ANY HELP WOULD BE APPRECIATED.
THANKS
HAPPY NEW YEAR
BILL

  • Guest asked 7 years ago
  • last active 7 years ago
0 votes
2k views

I have the above Model refrigerator freezer and have been experiencing the ice up problem. I would like to know if the P-Trap kit is available for my model. If so, is it your opinion that this would solve the problem, and what is the cost of the kit?
Thanks!
Les Hooker

  • Les Hooker asked 10 years ago
  • last active 10 years ago
0 votes
2k views

replaced board on Kenmore freezer 24hours ago part #216979600 was not running now its cold but flashing

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

I have customer with above model, and issue is freezer is not freezing to desired temperature, it only reach up to 2 centigrade, I change, thermistor/ temperature sensor. I check compressor running dry well, I also change relay and new capacitor. But still I am not able to reach temperature up to -10 and above, what should I check oe change the parts to recommended. Thank you.

  • Guest asked 5 years ago
  • last active 5 years ago
0 votes
2k views

This standalone freezer is not getting power to the compressor. Turned the defrost timer and still nothing. Not sure how to test the timer. Or test the cold control

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
2k views

My neighbor thinks it’s something to do with a board or the electronics failing.

  • Hugh asked 9 years ago
  • last active 9 years ago
0 votes
2k views

The lights on my control panel will not come on.

0 votes
2k views

Everything checks out on this as far as components. I did find the drain line frozen and advised them to thaw for up to 48hrs to ensure it melted completely. For some reason I didn’t think this happened on these models very often and kept assuming to find an issue with a part. Should I just have them monitor for proper operation? Would be great to know this was the cause.

1 vote
2k views

the unit says vacuum condenser.
however the middle section of the back wall is over flowing with Frost.

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

I think this is a simple freezer could it be the control board that fried up the comp relay and does this have a defrost timer on the back thanks

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

There is moisture building up in my freezer.

0 votes
2k views

My Frigidaire refrigerator runs too loud.

0 votes
2k views

I’ve checked evaporator coil for ice buildup. No ice, fan is working, freezer thermostat has continuity , freezer thermistor good, door seal in good shape and clean, no gaps, condenser is running but hot to touch, relay isn’t clicking, no unusual noises, door controller reading”high temperature” ,set on lowest setting #7 temperature is 23. Any ideas?

  • Guest asked 7 years ago
  • last active 7 years ago
0 votes
2k views

I have a customer that has a Kenmore upright freezer.. It’s reading “Hi-Temp”. “7 on the controls. Before I go and look at it, would you please send to me the service manual for this, or let me know WHERE you get them? Because, I looked on the Internet and couldn’t find it. Second, do you know why it’s reading high?

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

The temperature in the freezer at 17 degrees
I cleaned the coils and I feel cold air blowing inside the freezer as well

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

My Kemore freezer is not cooling properly

0 votes
2k views

I am not getting any power to the fan or compressor.
I disconnected the plug that leads from the power source to the box below the door switch.
there is power going into the box but not going out of it meaning supplying the compressor and fan ect

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

Can you tell me what could be causing this issue on a Frigidaire Freezer? It is having these problems: Not cooling

0 votes
2k views

My freezer just turns on for a short period of time then shuts off.

0 votes
2k views

My freezer is not cold enough.

0 votes
2k views

My GE freezer is not getting cold enough and water leaking on to floor.

0 votes
2k views

My freezer just starts then stops.

0 votes
2k views

Not cooling properly in freezer

0 votes
2k views

My washer is giving off a burning smell.

0 votes
2k views

My freezer is not cooling good enough.

0 votes
2k views

Need daignostic sheet or manual for model GBE10ESJBSB

0 votes
2k views

My icemaker has been making hollow icecubes.

0 votes
2k views

My freezer is leaking water from somewhere.

0 votes
2k views

My freezer is not level.

0 votes
2k views

THE “DOOR AJAR” ALARM KEEPS SOUNDING. IT STOPPED FOR ABOUT A WEEK AND THEN CAME BACK. I CHANGED THE DOOR SWITCH WITH NO EFFECT. THE UNIT IS COOLING WELL AND THE DOOR SHUTS PROPERLY. I’M THINKING IT’S IN THE BOARD. ANY THOUGHTS WOULD BE APPRECIATED.
THANKS

  • Guest asked 7 years ago
  • last active 7 years ago
Showing 31 - 60 of 83 results