1 vote
2k views

Got power, but won’t start

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
2k views

On this dryer the thermal fuse keeps going out, after it runs for awhile? What causes this problem? The vent is clear and is a short vent run.
If this keeps going out should you also replace the thermostats where is down by the heater, or should I look at the thermistor might be bad?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views
1 vote
2k views

Replaced belt, idler, and squeaky rear bearings first time.. Costumer called me back out two days after initial repair with same complaint.. I greased the stubs for front bearings, replaced front bearings, and replaced rear stubs. Is the costumer overloading? Is the motor possibly spinning too fast? What could be causing the issue to come back? Could it possibly be the motor?
(Lost actual model number the one I entered is same dryer design)

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
816 views

installation instructions for coin drop 7044160P. may need a special tool for access to screws…not sure if reprograming will be necessary…Thanks

  • Guest asked 3 years ago
  • last active 3 years ago
1 vote
2k views

so they say the dryer will go off mid cycle.
I checked the motor by letting it run and turning it back on and off and on a d it restarts no problem.
what may I be missing?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

I haven’t been on the call yet but I have an LG dryer that has a burning smell once it starts up

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

I AM TH NKING THIS MAY HAVE BEEN CAUSED BY CLOGGED UP VENT… OR POSSIBLY THE VENTED HOLES MAY ALSO BE CLOGGED OUTSIDE. NEED SOME IDEAS, BEFORE DIAGNOSING THIS MACHINE….

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
3k views

Hi,
I am trying to determine what part I need to fix my dryer EFME627UTT1. Essentially, the dryer won’t start. However, it is exhibiting other strange behavior. The dryer has been in service for about two years since, 9/2019.

When I try to start the dryer, it makes three beeping noises, as it would if the door was open. The door is of course closed however. I put the dryer in diagnostic mode and it displayed an error code of ‘EHd’, flashing as ‘E’ then ‘Hd’. I do not see that code listed in the Dryer Tech Data Sheet. The dryer has a wheel to rotate through the different dry cycles. The center of a wheel has LED lights on it, indicating the time left to complete the dry cycle in minutes. When I rotate through the different dry cycles, the timer doesn’t change as it normally would. It gets stuck on particular value, once at 45 minutes, once at 55, etc. Additionally, sometimes the previous mentioned LED light doesn’t come at all when I start the dryer. However, if I put the dryer in diagnostic mode, the light will then come on and display the error code ‘EHd’ as mentioned previously.

I have taken the dryer apart to check for lint buildup, I found some, but nothing extraordinary. I am assuming its some sort of electronic problem. From some googling it seems it might be the control board, but at around $150 I’d prefer not to miss the call on the diagnoses. Thanks for the help.

  • Guest asked 2 years ago
  • last active 2 years ago
1 vote
2k views

THIS GAS SAMSUNG DRYER IS GIVING THE ( HE ) ERROR CODE ,IT WILL RUN ON FLYFF ONLY WITHOUT GIVING THE CODE. SEEMS TO ME LIKE THE BOARD WOULD BE THE CULPRIT. ANY HELP WILL BE APPRECIATED AND IF VIDEO IS GIVEN IT WILL BE MORE APPRECIATED THANKS

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The unit will not power up I need the tech sheet and wiring diagram. 240vac ok and neutral line. Is it the I or main control? Or both?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

It starts up it glows then I get a hum from the gas valve but no gas comes out I put brand-new solenoids on it and I get the same symptom the gas valve just hums and then it stops humming it glows again and then it hums again every time it glows it hums

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

good starting point to troubleshoot this brand new machine…120v ac each leg including feeding back through neutral.5 volts difference between right hot leg and neutral. what the??????

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

checked components everything checked out fine motor seems it was running slow put new motor in still not spinning fast . what are the facts that affect the speed of rotation

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Kenmore dryer 110.66912690

I have checked the dryer and all signs pointed a defective blower motor
I am looking for a disassembly video for this particular model and particularly for replacing the blower motor

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
1k views
1 vote
2k views

I have disconnected all other cables from the EOC but I am having problems removing the heater relay power chord

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

it is an electric dryer.
the drum turns but will not heat

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

I have a dryer that will not start that kicks out a e5 error. I think its an E looks like an E with the top line gone

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

When I try to push start to get the control panel to light up. The display board just blinks and beeps once and won’t turn on. Its been doing this for a while and unplugging and plugging back in usually works but is not working anymore.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
1k views

On this model we have a problem where sensor dry doesn’t stop, clothing is hot, doesn’t shut off and does not go into cool down.

  • mra20168 asked 5 years ago
  • last active 5 years ago
1 vote
2k views

The high limit right thermostat on this unit which would cut power to the motor located on the right side of the heating element , when this goes out what usually is suspected or root cause of that?

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
2k views

My customer had an electrician look at her dryer. I’m guessing that he did a continuity test. And removed the “part” that sits on the side of the exhaust line. And he never came back to fix it. Well, that’s the story that I was told.
There are two wires and a little hole in the can that is about half way in back of the exhaust line. I checked out several websites, and I didn’t find a hole or a part that goes in the middle of the exhaust line. One person said that it is the drum outlet bias thermostat. But it looks like it’s located at the front of the dryer.
If you can shed any light on the subject I would greatly appreciate it. If I order that $64.00 part and it’s not the right part. Besides being stupid, I’d look stupid.
Thanks?

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
3k views

The gas duet dryer only lights up for touch up mode and 15 minutes. When I turn knob for different settings touch up still stays lit. Automatic controls will not work no matter were control knob is turned. I can adjust settings on right side including time and heat but everything else does nothing. The original complaint was a F01 code.

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

I have a combo / stackable washer dryer from Whirlpool. The customer complaint is that it doesn’t shut off. She tried all 3 cycles and it won’t turn off.

Is there a way to check / test the timer? To make sure it’s not anything else. I don’t want to spend the money for a timer ONLY to find out that it could be something else.

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
2k views

The dryer makes a loud metal in metal sound when it it runs.
Did notice it dose lighten up when there is a lot in the dryer

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

This dryer became hot and burned up the thermostat completely and some burn marks on the metal inside the machine. I replaced both thermostats, the heating element was grounded so I replaced it also. After reassembling unit and running a few minutes a HE error code came on. We had the vent cleaned and I replaced the thermistor. Unit was used for 2 days and the HE error code has returned.

Any ideas of what to do now?

Thomas Butler
Cell 210 209 3029

  • Guest asked 7 years ago
  • last active 7 years ago
0 votes
2k views

Wanted to know on the thermostat mounted on the heater next to the thermo fuse. It has 1.4 k ohms of resistance. That’s with one lead of the terminal so you don’t measure anything else in the circuit. Can you tell me how this part works? Just would like to know for my own knowledge. Some have 4 wires on them? So how do they work?

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

I need to replace the door hinges. can you tell me how to get to the hinge screws?

0 votes
3k views

So I changed the coils and the igniter and the senser.
The falme still will go on for 5 to ten seconds and then go off.
And will repeat about 1 minute later
I have have taken the vent off of the back and no difference

  • Guest asked 8 years ago
  • last active 8 years ago
Showing 31 - 60 of 1k results