0 votes
2k views

are you sure your video for ice maker removal is complete?

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
6k views

Hi thanks for your video on how to replace my ice maker it worked great. However my ice maker still does not make ice. It seems to cycle one time and then quit. So if I reset it it may make one tray and that’s all. Same results with the old ice maker I replaced. Any ideas?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

Hi!
The problem is the following:
1. After turning on of a refrigerator, it works for ~2 hours, temp. goes down to -20 and +5 in freezer and cooling chamber, compressor stops
2. Then, after 10-15 minutes, it tries to start for 8-10 seconds, producing loud clicks and then stops. Freezer fan is working all the time.
3. Temp. goes up to +10 in both cameras, producing A1 or A2 alert.
If I give him a rest for 4-5 hours, this cycle repeats.
But some times (I don’t know why) this scheme breaks – compressor works (normally?), but temp. in cooling chamber rises up +10, meanwhile temp. in freezer drops to -26-27.
Thus, there is strange behavior – sometimes it seems to make vacuum in freezer, after the door is closed.

  • Anton asked 9 years ago
  • last active 9 years ago
0 votes
3k views

My fridge isn’t cooling. The evaporator is only frosted on about the top 1″ of the evaporator. I’m aware that the evaporators are notorious for leaking. How do I locate the leak? Will a leak that small show up with a bubble type solution, or do I use a sniffer?
When it comes time to evacuate the system, I have manifold gauges, but they’re set up for automotive R134a. What are the correct fittings for the R12 system? It looks like 1/4″ flare, but I can’t tell for sure. In the automotive world the low and High side have different size fittings, but on the fridge they look to be the same.

Thanks,
Don

  • Don Coulter asked 10 years ago
  • last active 10 years ago
0 votes
3k views

My Amana frig & freezer (model#ACD2234HRB) were both warm, although fan would still run. After hearing a clicking & humming sound.The information I found noted that it was more than likely a bad relay/starter/overload then compressor. So I replaced the starter relay/overload/capacitor(?), part#W10613606 . After replacing it was making the same sound and clicking on and off, also still no cooling to the freezer or frig. But after pulling out the relay to check connections, I noticed the relay/overload was hot to the touch. I don’t have a volt meter to check the compressor or parts. Bad part?

I ordered a new part, just in case it was bad. The same thing, happens hums ,clicks on and off, repeats itself. Will not get compressor running. Relay/overload is hot to touch. Don’t have a volt meter to check compressor.

  • ROBERT asked 9 years ago
  • last active 9 years ago
0 votes
57k views

Have E 22 fault code which I know is the fresh food fan. Problem is code will not reset and nothing else will start up on the unit. Can here the control board click but compressor never cuts on. Any ideas?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

First, your subzero refrige coil repair video is great!!

We have two Subero units with the 2 compressors in a tray. The 700 series and also a 427 wine cooler with lower drawers.

These units are a nightmare to work on due to limited access.

Since there is nothing obvious about how one might be able to ever get to the back compressor for service, a video would be a huge help.

Are your tech people familiar with these units with the tray, and would they consider a video?

If not, is there anyone there who I could talk to on the phone about the tray style subzeros?

Thanks

  • ernie asked 10 years ago
  • last active 10 years ago
0 votes
6k views

My fridge stopped working after our neutral line in the house was severed blowing most appliances not on protectors. I replaced the control board hoping it would fix it like my stove but not so.
Reprogramed to code 12 and the board is working correctly fan comes on but make a chugging sound (did that when it worked right) but no compressor. I looked at the wiring diagram and see a relay for the compressor, could this be it or is there another fuse or issue I may have. How do I trouble shoot this from here? Or is my fridge beyond repair?

  • Drew asked 10 years ago
  • last active 10 years ago
0 votes
3k views

Whirlpool Refrigerator French door bottom freezer. The unit is all iced up where the Ice maker is? How to you take the Ice maker out? It has all snap parts with screws to come out.

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

SPECIFICALLY THE PROCEDURE TO RECHARGE THE SYSTEM AND SCHEMATIC.

TX

  • Guest asked 7 years ago
  • last active 7 years ago
0 votes
17k views

refrigerator is not cooling at all but the compressor is running

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

Just looking for any service pointers ,, videos ,, wiring diagrams and diagnostics for this icemaker ..

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
3k views

I have had two compressors this week that would not start. I usually place a 3n1 on them to test them and then replace the OEM start device. On these two, one a frigidaire and the other a Jenn-air, the OEM parts would not start the compressors. I ended up leaving the 3n1 kits on them. Is this the only option short of replacing the compressors? I don’t do sealed system work. Thank you in advance.

  • Danny S asked 9 years ago
  • last active 9 years ago
0 votes
5k views

The ice maker door was clicking. I put a new HV circuit board in the back of the fridge and that stopped the ice maker noise. Now the front panel is flashing PE0000. The compressor sounds like it is always running. The front will let me dispense water, but nothing else. It will not respond to any button trying to reprogram it. I tried the Door alarm button and held it for a while and nothing. tried the Water button and held it for a while and nothing. When I push the + Or – on the refrigerator side the display will show ICE or H20 in the display. but nothing else will respond.

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
3k views

About 1.5 weeks ago our freezer section started warming up, to the point where some things were frozen and others weren’t. We cleaned things up from the vents and adjusted the settings but it got worse, to the point where it wasn’t close to freezing a couple days ago, which is when I got serious about finding what was happening.

I took the back off and found the compressor fan had an obstruction which I removed (poor mouse, I have no idea how he got in the house as we’ve never seen any before), it span right up and I figured everything would be fine after that. Things were quite warm/hot near the fan but cooled off quickly after the fan was working. The fan spins fast and has great airflow, there wasn’t much dust so I cleaned up it, put the cover back on, and left it running overnight.

The next day the freezer was barely cooler than room temperature. I removed the back panel in the freezer and found a big chunk of ice around the top/beginning of the evaporator unit (big meaning perhaps 3 inches in diameter in an oval shape), a little frost on the pipe leading to the radiator but only a little at the beginning of the radiator. I turned it off for a couple hours to let it all melt away.

After it had melted I turned it back on, a couple hours later the beginning of the radiator has a tiny bit of frost but very little actual cooling happening.

A friend who has more experience than I (and a clamp-on ammeter) checked the compressor and we can hear the relay click on and it will stay on using about 10 amps for about 10 seconds and then click off for a few minutes, repeat. Otherwise the compressor fan and evaporator fans are working fine, we just have no cooling. My friends thought is it is the compressor, perhaps locked up from getting too hot.

Any other things to try or is it time to get a new fridge? Thanks for any advice.

  • Airin asked 10 years ago
  • last active 9 years ago
0 votes
3k views

I need some advice from our subzero experts.
Complaint: Not Making Ice.
We found the unit with the icemaker arm bent around from the bucket being pushed back on the arm.
We replaced the icemaker and as the water level was low and it is in a rental home we removed the filter and installed a factory by pass plug.
I started the unit in Max Ice. The icemaker cycled around twice and filled to the correct water level. We thought all was good and stopped to double check it the next day, No Ice.
I checked everything over again, drawer switch etc. ok.
After posting on psanet we replaced the complete water valve w/flow sensor. I opened the valve sensor and found it had droppings in it. We thought we were ok.
I started the icemaker again on Max ice and stopped to check it again 2 days later. Still No Ice.
The wiring seems good . Power to the flow sensor comes from the Low Voltage Board and Power to the icemaker comes from the high voltage board.
Factory tech line doesn’t think it is a board.
Any advice would really be appreciated.
Thanks in advance.

0 votes
942 views

Hi,
I am troubleshooting a no LED light issue on this unit, All the LEDs work except the 5 on the roof of the refrigerator. The schematic shows that the 5 fridge roof LED’s are divided into 2 series circuits, 3 in one series and 2 in the other going back to the LED Driver board for the DC source. Both of these strings are not working, I have diagnosed that the LED Driver board is partially defective .

The problem is, it is not shown in any service literature, ANYWHERE. The visual shows it is located next to the control board along with the power supply, The only part shown in the exploded diagram is the Control board itself, Whirlpool W11161172. If you do a parts list search for LED Driver, it does not generate any hits. I am at a loss, I have check multiple sources including the Factory SM with no luck.

I need the part number for the LED Driver Board! Why is it not shown or listed anywhere? I wasted 2 hours looking!!!

Thanks 🙂
Tom
609 418 0278

  • Guest asked 3 years ago
  • last active 3 years ago
0 votes
2k views

Condensation back wall in refrigerator and behind ice maker

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
1k views

No matter where the control is set it freezes every thing.
How do I test this unit?
I need a service manual and tech sheet and any advice you can give

  • Guest asked 3 years ago
  • last active 3 years ago
0 votes
2k views

This is a French door refrigerator. The ice room drain freezes up and the air vents fill with water and freeze.
Has frigidaire ever found a sure fix?

  • Guest asked 4 years ago
  • last active 4 years ago
0 votes
6k views

get water but want make ice

  • aaron asked 10 years ago
  • last active 8 years ago
0 votes
24k views

Frigidaire refrigerator fphg2399pf1 is dead. No lights . . . not working. Tested outlet. Have electrical diagram. Mother board has power. Ordered new motherboard. Did not fix.

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

We replaced the master controller board and followed instructions to program the the refrigerator. When entering last number and pressing the final key the frig beeps instead of temparature lights showing up. What is still wrong?

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
5k views

I ordered the part 819160 .It is oem.The installation instructions list four procedures .Does this unit have start and run capacitors? It has a battery sized one and a part that is wired to it with a blue wire and red wire.The part has a copper winding on it.This part plugs into the compressor,is it the run cap?The big cap has two red and one blue wires connected to it.Can send pictures.How do I wire this?

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

Condenser fan cycling on and off every 10 seconds. everything else is working fine.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Customer said that ” Feezer works fine. Its cold in there but the refrigerator is warm. ” I have handled this symptom before on other manufacturers but dont want to assume same cause. Usually frost build up in evaporator coils in freezer section which constricts airflow to fridge section. Should I test defrost heater before testing defrost thermostat or defrost control ?

Kenmore fridge

Model Number
106.57036601
What have you tried so far?
Customer said that ” Feezer works fine. Its cold in there but the refrigerator is warm. ” I have handled this symptom before on other manufacturers but dont want to assume same cause. Usually frost build up in evaporator coils in freezer section which constricts airflow to fridge section. Should I test defrost heater before testing defrost thermostat or defrost control ?

Refrigerator Kenmore
Share
semperfi asked 3 days ago
Answers (1)
Sort by: Newest First
0
0
Hello
You need to check first if their is a heavy even frost build up on the coil. Then next do a continuity test on the heater. If the heater has continuity, then check the defrost thermostat. If the heater and therm. are good then replace the adaptive defrost control.
Information Links
106.57036601 Manual Sears refrigerator | Adaptive Defrost control | 4388932 Defrost control video

  • Guest asked 8 years ago
  • last active 8 years ago
0 votes
2k views

The unit is showing me a R10a code that the ice maker sensor is open or shorted. But all the tests are fine for the Ice maker sensor. the temper and ohms correspond to the chart and the dc voltage is 3.0 at 39000 ohms. The ice is forming on the inside of the refrigerator corresponding to the position of the air passage from the freezer to the ice room in the refrigerator. That is also where the water under the pantry drawer is coming and not the fresh food evaporator drain. It said in a manual for another samsung to check the thermister reading at the display but I don’t see any information how to program it to show that or any thermistor temperature except the normal operation readings of the actual temperatures. Isn’t there some way to run the damper and lights and evaporator fans ect……? Is there a better service manual for this and if you have ever seen this kind of freezing in the air passage, what did you do?

  • Guest asked 6 years ago
  • last active 6 years ago
0 votes
3k views

Hello, I love your new website.
My customer has a GE French Door fridge with the freezer on the bottom. I think the board that controls the fans is bad. I am the forth technician to service this fridge. She has had nothing but problems with it since she bought it. A year after, GE replaced the compressor. After that 3 boards were replaced. And more! Now this?..

  • Guest asked 8 years ago
  • last active 8 years ago