1 vote
2k views

Order the Module, dispenser – part 242074204 which they substitute with part 24074216. The part looks a little different but the big issue is the wiring harness is totally different. So what do you do with a part like this?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

On arrival motor in door constantly running icemaker stuck in harvest overheating and no ice on front user interface flashing

  • dwoods asked 6 years ago
  • last active 6 years ago
1 vote
1k views

how to force harvest on flex icemaker

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
953 views

I replaced the whole timer because the thermostat was damaged but now even with new timer including mother board and thermostat lights are flickering and timer is making a ticking sound and it doesn’t start

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

No Cool. Both the refrigerator and freezer. I have heard the compressor kick on. no error codes, temp on door says what it should be, not what it is.

what else do I need to trouble shoot?

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

First there is no diagnostic tech sheet in the unit. The damper is open and the freezer section is below zero. The refrigerator is 66. I could not test the unit with out the tech sheet. I suspect the freezer section is frosted.

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The unit is making a loud humming noise like a fan. The lower freezer unit is not freezing. It is cold . The upper unit seems to be working. I put a thermometer in and the top part is staying at 33 degrees. No error codes on the unit.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
3k views

Do you have a tech manual for fridge model WSF26C3EXF01 thanks

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

The unit has a linear compressor. I have no experience with a linear. Does it have a separate controller? or does the main control broad operate it. The compressor was receiving voltage and it was drawing current. The unit is 2 years old. Or do I need to evacuate the Freon and recharge, and look for a leak? Thanks for any help.

1 vote
2k views

Customer did a total meltdown and problem still remains. Freezer temp is 0 degrees and fridge is at 24 degrees. Water line frozen again.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

The morning after an electrical storm the temperature control display shows “88 88” with the second 88 blinking and the controls do not work.
The refrigerator and freezer seem to be working but I have no control over the temperature. Is there a way (sequence) to reset the display or
have I lost a:
Main Circuit Board
Power Control Board
LED Light Board

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

will not make ice but has water to the ice maker but will not fill

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

i hope I’m not going to be charged twice for the same question. The control board, defrost themostat and heater have been replaced. That leaves the thermistor not thermostat!
how do you check the thermistor (located left bottom of the evaporator cover) and is there an easy way to replace it.
the tech sheet does not go into this….in fact i found the color wiring different on the model I’m working on from the tech sheet (you gave me).

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
1k views

There’s is lots of frost and hard ice build up on ice maker and auger motor assembly and on the ice and around the ice container. Only on the top half of freezer section. Everything is cooling/freezing fine. Any ideas what could cause this?

Thanks, Allen

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
2k views

I have changed the water valve and it still freezes up. I have ran the diagnostics and the ice room temperature sensor is good, showing 3 degrees. The icemaker test is good. When I de ice the fill tube it will work and make ice for less than a day then refreeze.
It has done this 3 times.

The first time I found it froze and tried to run the diagnostics it would not work until I unplugged it and restarted it then it was ok.
What is causing this problem. The FILTER is good and so is the water pressure.
Is there a service bulletin on this or some other issue?
Or what?

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
983 views

To whom it may concern,
I have a Whirlpool WRF757SDEM refrigerator that has cooling issues in the refrigerator section of the unit;not the freezer . The bottom fresh drawer is ~ 33 degrees, the 3 drawers above that are ~ 40 degrees and the upper main is ~ 47 degrees.These temperatures have been verified by placing thermometers in each section. Due to this elevated temperature we also have had to shut the iced maker off as the ice would melt in the door compartment causing water to run out the chute. I have had a large amount of ice forming behind the bottom drawer ( the one at ~ 33 degrees) and have had to remove this 3 times as it build up there and has caused issues shutting that drawer. The ice was in all the vents located there and I had to take care so it would not get damaged. The freezer portion of this unit works fine and freezes ice in ~ 30 minutes.
I am hoping there is a repair for this erratic cooling as the unit is barely 6 years old and is just out of warranty.
Any and all assistance would be greatly appreciated.

  • Guest asked 2 years ago
  • last active 2 years ago
1 vote
2k views

Customer says fridge is warm on both sides, i am thinking it is a defrost problem so my question is where is the adc control or the defrost timer on this beast?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

Where is the water coming from? Is there a water tank or evaporator in the refrig. section? Do you have any technical information or service manual?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

there is power comeing to the unit.
and it goes to the computer board.
but then it stops.
I do not get any fans and light.
no display on the door water dispenser.
we are not getting any power

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Is there a way to run a diagnostic test on this unit? The Tech sheet is very basic wiring diagram only. I need to verify if I am on the right track.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Is this the damper or the thermister ? I ‘d like some technical advice on this unit.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

I need to replace the fresh food evaporator fan motor and I’m having trouble removing the access panel to the motor.
Thanks for any help you can give me!
Charley

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
1k views

THE UNIT ISN’T COOLING, THE MAIN BOARD HAS BEEN REPLACED AND THE COMPRESSOR IS RUNNING. I DON’T HAVE ANY PAPERWORK, IF YOU COULD TRY TO FIND THE COMPLETE SERVICE MANUAL I’D APPRECIATE. THANKS

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Noticed ice buildup under ice maker and back of housing.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

The ice fill tube to freeze up. The original technician replaced the ice maker. I was called due to the same problem and I replaced the water valve. I was just rec-called due to the same problem. The customer’s wife was a t home and added additional information. She indicated that everything will work fine for awhile when the fill tube has been manually defrosted. Then she will notice water leaking from the water line and then the next day the ice maker fill tube is frozen. The water valve was replaced and it doesn’t seem like it would occasional fail to seat for both the water and ice maker at the same time. Any idea what would cause this intermittent problem?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
3k views

The compressor is not running. The condenser fan is not running. The dispenser user interface is completely blank and unresponsive. The interior lights are working fine. No evaporator fan running either. I checked power at the outlet and it is fine. Checked the main board and don’t see any signs of anything wrong. Checked the user interface board and it looks fine too. The start relay and run capacitor test fine as well. Not sure where to check from here.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
3k views

The dispensor control board keeps blinking 0 37 no led lights on in fridge and freezer. Unit still running and cooling. Able to get lights back on but then go out again. Nothing dispensing either.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Customer replaced water filter, then valve. Still leaking from dispenser.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

I TRY TO REEPLECE THE INTERFACE WATER DISPENSER U HAVE ANY VIDEO O TECH SUPPORT

  • Guest asked 5 years ago
  • last active 5 years ago
Showing 31 - 60 of 3k results