0 votes
3k views

My Roper dryer is not tumbling properly.

0 votes
3k views

My Maytag dryer is making a growling noise.

0 votes
3k views

My Kenmore refrigerator is not getting cold enough in the fresh food section

0 votes
3k views

My LG washer is making a humming noise.

0 votes
2k views

is half of the dual broil element suppose to come on in bake mode?

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

GOOD MORNING. I AM TOLD THE WASHER FILLS WITH WATER AND WILL NOT ADVANCE TO THE NEXT CYCLE. I DID NOT LOOK AT IT YET, BUT WOULD LOVE SOME IDEAS. THANKS, TODD FROM NY.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

A customer’s dishwasher heater is coming on early, and the unit is not filling up with water. While this could be an issue with the water valve, the heater is coming on at the incorrect time.

Have you ever come across an issue like this before? Bad board?

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
4k views

Hearing a loud banging or popping noise emanating from the refrigerator. The sound is intermittent , maybe only happening once a day, but sometimes happens more often. What would be causing this to happen and can it be fixed?

0 votes
3k views

There’s an intermittent fan type noise that seems to be coming from the fridge section. The noise stops when the door is opened making it hard to hear correctly. I entered Forced Operations, FF step, to make sure all the fans are running. I opened the left fridge section door, defeated the door switch using a magnet, and listened to the fans. Sounds like it’s coming from behind the evaporator cover.

0 votes
3k views

Coming across multiple bottom mount and french door refrigerators that are getting water leaking down under the crispers from a frozen drain. Is there a known fix for this?

0 votes
3k views

I read online that this could possibly be caused by the air dome sending an incorrect water level reading to the timer. Is that true?

0 votes
17k views

Seems like the main oven door is not contacting with the latch/light switch.

0 votes
3k views

After replacing the ice maker and pushing the test button it rotated and filled good. 24 hours later there is no ice. it seems after replacing the ice maker someone pushed the ice off button. I tested the ice maker again and it cycled, dumped ice and filled again. How long should it take to harvest ice? Would there be anything else that would cause the ice not to be made besides the water valve, high temp, ice button set to off or faulty ice maker?

Just a side note, I did see some frost on the ice maker and on the top shelf but not on the back wall. I checked the door gasket and it seems to be in good shape and holding a good seal. I figured this was from someone not closing the door properly. Any ideas you may have would be greatly appreciated.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
4k views

HOW DO I REPLACE WR60X10330 FAN MOTOR? OR WHAT ELSE COULD IT BE? HOW DO I GET TO THE FAN MOTOR TO REPLACE IT? ITS NOT MAKING ENOUGH ICE AND TEMP IN ICE MAKER IS ONLY 10 DEG. THE FIRST COMPLAINT WAS NOT WATER COMING OUT THE DOOR AND NO ICE AT ALL. REPLACE INLET FILTER AND INLET AND GOT WATER BUT NO ICE REPLACE ICE MAKER AND KNOW MAKES ONLY ABOUT 20 ICE CUBES IN 24 HRS. THIS IS MY FIRST TIME ASKING YOU A QUESTION I HAVE OWN MY OWN SERVICE COMPANY FOR OVER 30 YEARS AND THE STUFF IS GETTING WAY TO COMPLACATED

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views
0 votes
3k views

We are having an issue with a Kenmore SXS refrigerator MN: 253.54629406 that keeps defrosting up. At first when we came out there we found it frosted up. The heaters and bi metal were working so we replaced the ADC board and forced into to defrost and heaters came on. Customer called back one week later and said same problem. We went back out there and thought the board we replaced the new ADC board, because we could not force it into defrost plus cold control, wiring assembly and dampener control and bi metal.Customer called back and is saying refrigerator works fine for a week then freezers up(same issue) Any help would be appreciated. Thank you.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

I cannot remove rack in freezer so I can access and remove panels to check drain tube. I have water under the veggie drawers on bottom of frig. The video says this is caused by a
blocked drain in the freezer and I should pour hot water to release it. Maybe this model does not allow it to be checked so how do I stop the water from accumulating under the drawer. Is there another method for this model- 253.61874400? Is there a phone number so I can talk to a serviceman and if necessary have a home visit? I would like to know how much this would cost in addition to this $25 for my one question. I would prefer a simple answer without advanced service at my home. We like Kenmore but this is not customer friendly. We called the parts and was only referred to this site. Please respond immediately since our freezer is defrosting. Sincerely, Norm Peterson

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

GOOD MORNING. I CHANGED THE COILS, AND THE BURNER WILL NOT LITE. WHEN THE START BUTTON IS PUSHED THERE IS SOME WHAT OF A CLICK AND THEN A VERY LOUD WHINNING-BUZZING SOUND, THEN THE ELEMENT GLOWS, THEN AFTER ABOUT 10 SECONDS A SECOND CLICK, THEN IT SHUTS DOWN. IT WILL REPEAT THIS CYCLE OVER AND OVER. I HAVE CONTINUITY AT THE FLAME SENSOR AND THE IGNITER OHMED OUT AT .5, I BELIEVE, BUT NO CONTINUITY BUZZ. I THEN TOUCHED THE IGNITER SOME WHAT LIGHTLY AND IT BROKE IN TWO VERY EASILY. I HAVE A LOCAL PARTS PLACE THAT WILL TEST THE VALVE IF I TAKE IT TO HIM. I HAVE HEARD OF GAS STOVES NOT IGNITING BECAUSE THE IGNITER IS STARTING TO FAIL AND DOES NOT REACH PROPER TEMP FOR THE GAS TO FLOW, MIGHT THIS BE SIMILAR? THANKS, TODD FROM NY.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
6k views

Styrofoam insulation for evaporator has become saturated with water from a backed up drain.
Anyone have one I can purchase this part ? DA62-01766A.
Thanks,

0 votes
6k views

When I arrived the water valve put in a little water and then the drain pump came and continuously ran and when I went into service mode the error codes E30 and E54 were in the history. I went through the test options and made it T06 which is the pressure switch test and it went into error. I put a pressure switch on the washer and problem still occurring with the same symptoms. Thanks in advance for any help

0 votes
5k views

Need information on servicing this type of icemaker!

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

Kenmore brand. This fridge will cut off at times, if you bump the cold control slightly it will turn on.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
4k views

compressor is running ,evap fan is working,defrost bi metal is good,defrost sensor good,refrigerator holding the temp,very little
frost on the freezer evap,any suggestion befor I order the board. Thanks.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

Hi Folks,

This is a fairly new unit that was in storage for a few months. There is water to the water valve. Water will not go into the unit and there is no power to the water valve. The fill led is blinking green. The unit does lock! No tech sheet to be found in the usual place. Any ideas for the location of the tech sheet or the diagnoses as the what is wrong with this unit?.

All help greatly appreciated.

Thank you,

Jan
Barney’s Appliance
Palm Bay, FL

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

I have two error codes SD & F71 code. Talks about tub not seating properly. I feel like this is the case(thought it was a bit rough when I lifted and dropped).
However, in service mode it did the medium and high speed spin. When I set it for a drain/spin cycle(14min.) it went to 12 stayed there for over 5min and then went into SD code.
Am I missing something?

0 votes
3k views

How do access the evap fan motor on a bottom freezer French door refrig. Never had one apart

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

I am working on a Kenmore HE3. I have replaced the coils and the ( cycling thermostat ). And the burner continues to run for about 10-12 seconds then shuts off. After a few minutes, the igniter comes on, the gas valve opens up and the burner starts and run for 10 seconds or so, then shuts off, and the cycle continues.
I think it’s the gas valve, but before my customer spends that kind of money. I want a second opinion. What do you think, and why?

Bob
I would appreciate a quick call if possible. 609-437-7436
Robertdennis3382@yahoo.com

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

THE CUSTOMER IS TELLING ME THAT THERE IS HEAT, BUT THE DRYING IS TAKING TOO LONG. I DID NOT GO TO SEE IT YET, COULD SOMEONE WALK ME THROUGH THE DIAGNOSIS? THANK, TODD FROM NY.

  • Guest asked 10 years ago
  • last active 10 years ago
0 votes
3k views

My Whirlpool refrigerator is leaking water I think from ice maker ?

0 votes
3k views

My gas Kenmore dryer is not heating.

Showing 7531 - 7560 of 9k results