This second ground wire may have connected somewhere – I’am not sure. I went behind panel to check on ice buildup because the ice was melting and refrigerator not cold. Right now the freezer seems fine with the fan working somewhat but no cool air is entering to refrigerator area. I can certainly use your assistance.
- Michael asked 10 years ago
- last active 10 years ago
HI FOLKS,
I AM GETTING THE ERROR CODE ER RF. THIS PERTAINS TO A FAN IN THE UNIT BUT WHAT FAN? THERE ARE THREE. I INTENED TO CHECK IT FROM THE MAIN BOARD NEXT WEEK BUT I WANT BE ON THE CORRECT PATH. ALL INFORMATIOIN GREATLY APPRECIATED.
NOTE: UNDER THE BRAND NAME I COULD NOT INSERT LG.
THANK YOU,
JAN
BARNEY’S APPLIANCE
- Guest asked 8 years ago
- last active 8 years ago
Ref is not cooling, no lights in the fresh food compartment and has a PF code. Previous tech replaced control board and user interface and still the same.
- mdhomeservices asked 5 years ago
- last active 5 years ago
I cannot get any pads to work to enter code
- Guest asked 7 years ago
- last active 7 years ago
The issue started with ice buildup on the bottom of the freezer. After watching your videos, I was able to correct this issue and had to unclog/defrost the drain line and replace the evaporator fan motor. During the repair, I’ve noticed that the light in the freezer does not always come on or go off when it should; it flickers intermittently. Also, the alarm continually goes off. I’ve also noticed that when I press upwards on the area where the light switch is in the freezer, the evaporator fan comes on. I believe that this is due to a short, but I am not sure how to access this area of the fridge, as I can see now way to enter into the covering. Please help!
- Guest asked 9 years ago
- last active 9 years ago
The ice and water dispenser buttons are stuck and not working, do I have to replace them individually? Haven’t got it apart yet to see if maybe it’s all one assembly I can order.
- Harley Clark asked 9 years ago
- last active 9 years ago
get water but want make ice
- aaron asked 10 years ago
- last active 8 years ago
Lg refridgerator LMXC23746D/00. Compressor is cooling in both the fridge and freezer but fans not running. Fans run while in the test mode when the control board button is hit
- Guest asked 6 years ago
- last active 6 years ago
Wisemotion is a linear compressor designed and manufactured by Embraco. How do I service this ?
- David Sutton asked 8 years ago
- last active 8 years ago
Steps on programing board.
- Guest asked 8 years ago
- last active 8 years ago
I would like to know how to put this refrigerator into test mode, some video for wach it thank you for the help.
- Victor12 asked 7 years ago
- last active 7 years ago
looking for a service manual or assistance if anyone has heard of this problem its is a french door with ice maker up in refrig section and we replaced the Ice maker and the fresh food thermistor problem customer is stating the ice cubes are soft and melting what might i be missing .
- Tony Zak asked 9 years ago
- last active 9 years ago
Leaking water, Solid chuck of ice in bin.
- Curtis Appliance Repair asked 6 years ago
- last active 6 years ago
I can dispense water but not ice. I took the ice maker out and found a couple ice cubes in the forms and some empty ones. It dropped one ice cube the other day. I couldn’t find an ice blockage anywhere. How do I know if I need a new ice maker , valve, or other part?
- Wade asked 10 years ago
- last active 8 years ago
My fridge stopped working after our neutral line in the house was severed blowing most appliances not on protectors. I replaced the control board hoping it would fix it like my stove but not so.
Reprogramed to code 12 and the board is working correctly fan comes on but make a chugging sound (did that when it worked right) but no compressor. I looked at the wiring diagram and see a relay for the compressor, could this be it or is there another fuse or issue I may have. How do I trouble shoot this from here? Or is my fridge beyond repair?
- Drew asked 10 years ago
- last active 10 years ago
How do you install the water tank assembly? I can see the water tank leaking causing water to pool in my refrigerator. I see where they exit the interior of the refrigerator, but can not locate where you connect the new part to the refrigerator. Thanks.
- Tammy Ratliff asked 10 years ago
- last active 10 years ago
fill tube gets frozen even when the water is turn off.
- Guest asked 7 years ago
- last active 7 years ago
Hi thanks for your video on how to replace my ice maker it worked great. However my ice maker still does not make ice. It seems to cycle one time and then quit. So if I reset it it may make one tray and that’s all. Same results with the old ice maker I replaced. Any ideas?
- Guest asked 9 years ago
- last active 9 years ago
My refrigerator is giving me a c21 error.
- Patrick's Appliance Service asked 4 years ago
- last active 4 years ago
Please can you tell me where the water valve is located on this refrigerator. water and ice not working. please attach video if there is one. thank for your help
- Guest asked 8 years ago
- last active 8 years ago
Can we get more advanced videos for example how to remove the bottom hinges off a Viking side-by-side refrigerator not specific to a model? Or how to replace hinges on a Viking or Thermidor or wolf range? Please more Advanced videos or links to some regarding more high end appliances this site only includes some minor repairs.
- Guest asked 7 years ago
- last active 7 years ago
I have a model Amana refrigerator and the refrigerator section went warm. We do not usually service the Whirlpool product lines usually sticking with Samsung, LG and GE as we are authorized for them and have access to their literature, etc.
Can anyone assist with some service information and any tips for this model? I understand looking at an exploded view that the unit is a single evaporator model with a damper control. Is there anything common that could cause the damper to malfunction or do you think I am even looking in the right area?
- Blake, Ace Appliance asked 9 years ago
- last active 9 years ago
This is a nice looking GE side by side fridge. Mold is all over the styrofoam and foam stripping in the FF evaporator area. So these mold spores are blowing all around the inside of the refrigerator and you can see that they are growing wherever there is moisture in the fridge. Is this a design flaw in the unit? Has anyone else dealt with this and been successful at getting rid of it? Even if I went through all the work of replacing the Styrofoam, freon lines insulation, and foam stripping I think it will return. The temps in the fresh food section were 48 degrees. I replaced the temperature sensors in the FF section. I could not find a part number for the sensor on the evaporator but I replaced it with a WR55X10025. I’m waiting to hear back from the customer to see if the fridge cools down to normal. Evaporator fan in FF working fine. Thank you for any advise.
- Don Kopecky asked 7 years ago
- last active 7 years ago
Model – PSC23NSTDSS Serial – VL445258
Says refrigerator side getting warm 54 degrees. Freezer side running zero.
Refrigerator temperature normal. Fresh food 36 and freezer 0. . Stated Monday afternoon. Left door open for 3 minutes to see if unit goes into liner protection and freezer fan runs on high. Works fine. Confirm damper/fan assembly in refrigerator working. . Air return clear. Run diagnostics test. Only thing that didn’t pass was temperature control panel to dispenser board communication. That failed. Did try my test control panel I carry in place of customers panel. Same results. Failed. Don’t really understand why temperature control panel talks to dispenser board when there is nothing on temperature control panel that controls anything on dispenser board. Refrigerator door switch is on side wall. Confirmed door switch is being activated by door. When door is one inch from closing, switch turns off interior lights. Currently have door switch taped closed. Did go ahead and do the system reset. . Thermistors passed testing, but then again you never know. Also is the picture of thermistor old style? Should I maybe upgrade them?
- Gary Williams asked 9 years ago
- last active 9 years ago
What is knob or dial under freezer door in kick plate for and do you adjust it? Temp controls in fridge .
- James asked 10 years ago
- last active 10 years ago
i have a kitchenaid french door refrigerator and the freezer is working fine but the refrigerator is freezing the food in refrigereator section
- Guest asked 6 years ago
- last active 6 years ago
Display shows error codes, Missing digits, Display will not light up, No ice through dispenser, Buttons will not respond.
- Harley Clark asked 6 years ago
- last active 6 years ago
Freezer fine but fresh food section coils iced over. Tested defrost sensor seems fine. COULD NOT LOCATE DEFROST HEATER. All the wiring in the nearby Molex runs wires to damper door and evaporator fan which both were working.
- Guest asked 7 years ago
- last active 7 years ago