Left rail stuck.. freezer door will not open. Looks like rail is lock in mid Position

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
1k views

The water valve for this refrigerator is leaking. The problem is that the valve LG is saying that it needs is a MJX41178908, the mounting is perfect but this valve is a single solenoid valve. The original vale is a dual solenoid valve but they give no instructions to convert. I wanted to see if you have run into something like this before, get advice, or see if there is any instructions on this. There is another valve MJX41869202. THe valve that is in there is way different than both. Amy advice or research would be greatly appreciated.

1 vote
2k views

Samsung refrigerator model code RF22N9781SG/AA Ice maker is frozen. I cannot get the ice container removed.
How can the ice maker be defrosted without having to disconnect the refrigerator for 24 hours .
please send service manual

  • Guest asked 2 years ago
  • last active 2 years ago
1 vote
378 views

watched your video, ordered a new capacitor and relay module. Installed new unit same issue. Any other solutions? Refrigerator is only 13 months old.

  • Guest asked 7 months ago
  • last active 7 months ago
1 vote
2k views

THIS A DUAL EVAP COIL UNIT. I UNPLUGGED THE UNIT AFTER 8 SECONDS TO PUT REVERSING VALVE IN THE “HOME” POSITION. I WEIGHED IN THE REFRIGERANT. PRESSURES ARE 20 LBS SUCTION AND 125 ON THE HIGH SIDE, WITH NO COOLING.
I DON’T HAVE ANY PAPEWORK ON THIS UNIT, SO I’M NOT SURE THAT THIS WAS THE CORRECT PROCEDURE RE; THE REVERSING VALVE.

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

I checked to see if the compressor is running-yes. I checked the evaporator and condenser fan motors are running-yes.
I’m not sure where to look next?

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

THE COMPRESSOR IS RUNNING AT -1.7inHg. NEITHER EVAPORATOR FAN IS RUNNING AND IT’S NOT COOLING. I HAVEN’T WORKED A LOT ON THESE VARIABLE SPEED UNITS. I GUESS I NEED TO FIND THE DIAGNOSTIC SHEETS AND WHAT EVERY ELSE YOU COULD DIG UP. TX

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
17k views

The refrigerator was not running. I look at the main board and observed the green light on the board blinking 6 times continuously after 3 seconds it blinks 6 times continuously. is it an error code or what. The tech sheet said nothing about the blinking light on the main board.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

the compressor will not kick on’
everything is else is working
on this unit i did not see a relay
please advise as to what it can be

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Makes ice seldom leave and then melts and runs out onto the floor did it in error code for icemaker test drive noted in bed going to replace icemaker but I’m assuming I have a cooling issues also

  • dwoods asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Freezer was not cool enough interface shows a bad freezer sensor replace sensor interface still shows bad sensor tryed to put into diagonstic the whole face went blank and lights inside fresh food side and freezer went out and will not come back on. Unpluged it several times waited 2-3 minutes still will not reset are come on. Replaced boards and still nothing. it’s been about a week now.

  • dan0418 asked 6 years ago
  • last active 6 years ago
1 vote
1k views

I just became a premium member just for situations like this.
Can you guide me to a video on how to replace the damper part # WR60X10062 ? I can’t find one?
Thanks
Dale Stoltz
Quick and Easy Appliance

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
22k views

The fridge temp is to high. I found on the lower left side of the fridge a small block of ice, where the vent should be. I thawed out the ice turned the fridge back on, and felt no air flow ( either wat ).
The top left side vent was blowing cool air. Not a lot of air flow, but I could feel air moving.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

My apologies if this is a duplicate request.
Freezer and refrigerator evaporators keep freezing up.
Unit is bottom freezer. What else should I be looking at to repair unit.
Thanks
Gaspare

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
4k views

The flap of ice dispenser (or Ice Route Assy) that usually only open when dispensing ice is opening and closing continuously. It only stop once I disconnect the wire of the ice route assy on he back of the dispenser display. Can I resolve the issue by changing a new Ice Route Assy? Or is this a computer board issue?
I’ve also had local technician check out the fridge; they told me I need to get the entire upper left door (the door with the dispenser) replaced.
I am not quite sure if this can solve the issue since it is quite expensive to replace the door. I want to make sure this is the right way to solve it before I say yes to replace the door.

  • Guest asked 4 years ago
  • last active 4 years ago
1 vote
3k views

I just need to know how to detach the Blue water hose from the back top right side of the refrigerator.
I pulled the grey one easy but the purple one I can’t pull it it is stock, my question is if the hose you detach it from the back or from the inside of the refrigerator where the ice maker compartment Is.
Please provide me with the installation immediately, thank you.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

How can I do a test on the electronic defrost control?

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
1k views

no water or ice disp and light

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Can’t figure out what is going on with this refrigerators icemaker. I have changed the icemaker, and it still will not cylce. The optic sensor will come on for awhile then will go off after a bit, until I unplug the unit, then they will reset at that point. The water valve is good. I put in diagnostic mode and the optic sensor read as should, so I am not sure why this unit will not make ice. FYI all switches are good as well.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

The units evaporator was frozen. I cleaned evap and replaced the adc control. It had the old 1st generation so i replaced the new wiring for the orange adc now the damper is running all the time. I did notice the fresh food thermostat had three wires new wiring harness has two. When i installed i had the freezer thermostat off. first i turn the fresh thermo on fan came on and damper, then i turn fresh food control off fan turn off just like it is supposed and the damper motor kept running

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
3k views

This refrigerator is a side by side made by Whirlpool with the ice maker on the freezer door. Has electric eye, also on the freezer door.
Need to know how to make the icemaker run. Do these new style electric eye flash an error code?

1 vote
2k views

(Maytag french door, freezer on bottom.)
Bottom 65% of evaporator completely blocked, ice on both ends to wall of freezer, but almost zero ice in tray below evaporator. Damper door open at top, a “roaring” sound which suggests an air flow blockage (evaporator fan working). I followed your excellent video on checking for blocked drain (drain free, no “grommet” at bottom of tube, but no moisture in drain pan.)
Evaporator appears to NOT be defrosting automatically. I suspect a sensor problem or a control board problem.

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
2k views

My customer called me up and said that she heard a noise coming from the back of the fridge. Loud vibrating noise. The temp in the freezer was ok, but the fridge was high. I asked her if there was frost build up on the back of the freezer, she said no. She unplugged it. I stopped by, checked the continuity on the freezer evap fan, and hot none.
So, I bought a new one, put it in. It doesn’t seem to be working either. No air movement.

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The complaint is that the freezer works intermittently. Today they say the freezer and the refrigerator are about the same temperature

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The icemaker a Samsung, stalls out in the harvest position as if the heater is not working. Is there any repair on this item? The part number is WR30X10131

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

A customer calls me up and tells me that her fridge does not work. The temperature is dropping in both the freezer and fridge, but the light is on… nothing else is working

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

New bulbs burning too. Bulb outlets burned.. I’m assuming relay because the bulb outlet is just leads from the relay? Both bulbs hot because on same line. Please keep it simple

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

does not dispense water
does not dispense ice

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

freezer staying at 26 deg. fresh food at 34 deg. replaced main control board after finding only 3 volts d.c. on the inverter input from main control board.

  • Guest asked 6 years ago
  • last active 6 years ago
Showing 61 - 90 of 3k results