1 vote
2k views

A customer calls me up and tells me that her fridge does not work. The temperature is dropping in both the freezer and fridge, but the light is on… nothing else is working

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

have checked 240 coming into the dryer, have power to the main control board. is there anything else I should check. could a door switch cause it to not power up at all. the drum light does not light all displays are dead

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

I have replace door lock and door switch the washer door still buzzes when I close it doesn’t lock and start what could be the next problem these parts are brand-new do you think I could have a defective part or is there something else I need to check.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views
  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

How to test the ice maker voltages output?

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

How can I put this refrig.. in defrost mode

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

Gentlemen, could you provide me with a tech sheet or service manual for this g, e. Refrigerator.
Evaporator is frozen up unit does not defrost. I suspect defrost control issue. Defrost heaters check good with the ohm meter, defrost thermostat checks good. I noticed the thermistor has been replaced. If you could pass any service information to me it would be a great help and greatly appreciated.thank you very much.

  • Guest asked 7 years ago
  • last active 7 years ago
1 vote
2k views

This is a commercial whirlpool washer it says. I cannot get it in diagnostic mode.It says to unplug , start at 12 o clock, turn dial lt, rt, rt lt rt. the sense light blinks when I plug it in. then if you hit start it stops blinking. after about a minute or so the red lock light starts blinking. it will not throw a code. the sense light just stays on.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

The error code uL comes up every time the machine is used even when there is nothing in it. I tried a new rps sensor and didn’t fix the problem. I’m thinking it may be the main board. looking for help with this one.
Thanks, Charley

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Fills but does not drain goes through cycle except for drain

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

The high limit right thermostat on this unit which would cut power to the motor located on the right side of the heating element , when this goes out what usually is suspected or root cause of that?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

No turn on the top right and bottom right Burner

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

My customer called me up and said that she heard a noise coming from the back of the fridge. Loud vibrating noise. The temp in the freezer was ok, but the fridge was high. I asked her if there was frost build up on the back of the freezer, she said no. She unplugged it. I stopped by, checked the continuity on the freezer evap fan, and hot none.
So, I bought a new one, put it in. It doesn’t seem to be working either. No air movement.

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

Washer over filling onrinse sometmes

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

Water wont drain all way out of tub just stays in tub..When its trying to drain I can hear something making like a rattling noise and I can tell the pump is trying to work..

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
3k views

Diagnose why washer will not spin?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

Washer fills then stops.
I manually turn timer 1 notch for the machine to proceed, it then turns and stops
Machine won’t start cycle or agitate.
I turn timer to Spin cycle, It will only drain and won’t spin.

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views
  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

how do you take the door off to replace the soap dispenser?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

The complaint is that the freezer works intermittently. Today they say the freezer and the refrigerator are about the same temperature

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

Recently did sealed system work. Because heat exchanger was leaking refrigerant. Replaced evaporator and heat exchanger. Heating loop below the fridge looks perfect. Condenser clean. Condenser fan motor running. Evaporator and all other fans seem to be running and everything is plugged in and running properly…
But the display is flashing certain temperature control bars. Which if I recall correctly is an error code. The FRZ light is flashing and light bar 3/4/5/6 keeps flashing in numerical sequence. What is this error code indicating?

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

ORIGINAL COMPAINT WAS A WATER LEAK FROM BEHIND THE ICE DISPENCER HOLE. NOT FROM WATER DISPENCER TUBE. TURNING OFF WATER SUPPLY CURED LEAK, SO NOT ICE MELTING. THE SLOW DRIP IS COMING DOWN THE BACK SURFACE AREA WHERE YOU PLACE YOUR GLASS.

SEPERATE ISSUE: CUSTOMER WAS USING THE ICE DISPENCER AND MAY HAVE BEEN FILLING THE HOPPER WITH BAGGED ICE (NOT SURE. MAY HAVE BEEN LEFTOVER ICE FROM ICE MAKER). WHILE DISPENCING ICE A CHUNK OF PLASTIC DROPPED INTO HER GLASS. IT APPEARS TO BE SOME SORT OF ARM/LEVER? NOW THE ICE MAKER WILL ONLY DISPENCE CRUSHED ICE. I THINK IT IS PART OF THE ICE CRUSH MOTOR ASSY BUT I COULD NOT SEE WHERE IT CAME FROM. LINKAGE ON THE TUB MOVES THE FLAP IN THE ASSY BUT IT HANGS A LITTLE.

THANKS, GEORGE.

  • triadapp asked 8 years ago
  • last active 8 years ago
1 vote
2k views

On this dryer the thermal fuse keeps going out, after it runs for awhile? What causes this problem? The vent is clear and is a short vent run.
If this keeps going out should you also replace the thermostats where is down by the heater, or should I look at the thermistor might be bad?

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

the unit has a fairly new drain pump and i cleaned out the drain as well like 2 months ago
the customer called to say he has the same problem. the clothes dont ring out well

  • Guest asked 8 years ago
  • last active 8 years ago
1 vote
2k views

Viking range. Burners not clicking.
Model number vgsc3674qss.

A friend’s range. They said various burned clicked and didn’t light and finally none would light. I got there and none would click at all. I checked one of the spark switches and it had continuity when turned on. I cleaned that burner and still nothing, but I did not remove the base. The tiny screw holes were full of crap so I couldn’t even tell what kind of head was down there. I hope I don’t have to try to get them out!

I don’t want to order an expensive spark module until I’m sure what the problem is.

How should I troubleshoot this?
Tom

  • Guest asked 6 years ago
  • last active 6 years ago
1 vote
2k views

the ice dispenser when the button is pressed and released it keeps running

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
1k views

how to force harvest on flex icemaker

  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
2k views
  • Guest asked 5 years ago
  • last active 5 years ago
1 vote
1k views

The Door switch is good and if I unplug the interface then plug it back in it will clear for 15 second but still won’t respont to any commands. The power has been turned off for several minutes and makes no difference.

The tech sheet does not show any error codes. Do the 3 blinking led’s mean any thing. IF so , what?
Is there a manual for this.

  • Guest asked 5 years ago
  • last active 5 years ago