0 votes
4k views

I am not getting any display option. And it’s causing the unit not to cool. It is not on Sabbath mode and I am getting power to the display.. What else can I look for

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
15k views

I have a Whirlpool French Door Bottom Mount Refrigerator. The icemaker has a slow drip out of the front of the icemaker heater cover. The water slowly drips down into the front ice bin. the Ice bin in the front door builds up with ice and eventually the water starts to run out of the opening of the front door and the water and Ice dispenser unit installed on the front door.

How do I stop the water from dripping out of the icemaker front cover?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

the customer said that when the machine goes into spin it sounds like a truck

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

I HAVE TWO, OF THESE UNITS, WITH SEALED SYSTEM PROBLEMS. PREVIOUS TECHS CUT NUMEROUS REFRIGERATION LINES. I NEED INFO ON PUTTING UNITS INTO DIAGNOSTIC MODE, SPECIFICALLY IN PREPARATION TO FINDING LEAK OR LEAKS AND RECHARGING. I NEED TO GET THE REVERSING VALVE IN THE CORRECT POSITION, ETC

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

THE BURNERS WILL CLICK

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

Hello,
I followed your video for diagnosing my Kitchenaid (ksrl25fxms02) refrigerator’s ice maker as it had stopped producing ice.
I want to thank you for the clear presentation of the material. If was a refreshing change to have some clear, concise steps on interpreting the optical diagnostic codes and conducting the manual test of the ice maker’s harvest cycle that did not leave me wondering if I was doing something wrong.
Unfortunately, I am still getting mixed results that lead me to believe that perhaps the ice maker and the optical boards may both have problems.
I’m hoping that your experience will make some sense of what I am seeing and help me determine the best course of action.
After viewing your video, I unplugged my refrigerator, jumpered test points T and H then plugged the refrigerator back in and depressed the switch in the door so that the beam path was unbroken. I was surprised to see that the blinking led went from the 2 blink, 1 second pause code to a solid light. Previously, it continued the 2 blink, 1 second pause code no matter what i did. The harvest cycle never started during this first test, which led me to believe that the ice maker itself was bad.
I decided to repeat the test in precisely the same way and got a different result this time and a few additional times. In these subsequent tests, the led continued to blink in the 2 blink, 1 second pause pattern as it had before I followed the steps in your video and did not go to a solid light
This behavior leads me to suspect both the ice maker and the optical boards.
I wonder if you have observed this behavior before and if it is to be expected or if you have some thoughts on what the next steps should be.
Hopefully this makes sense.
Thank you

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

This unit is on city water and the city flushed the line and muddy water stopped up the filter. The customer replaced the filter and that is when the ice maker production almost stopped. I performed the harvest test and the water valve test and replaced the valve part # wpw10341329. I retested the water valve and it turned on and off OK. The nest day the customer called and said it still only made about 4 cubes. Does the water valve fill test deliver the precise amount of water in the test mode? What else can I test or do?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Customer called said the box would show sy. Ce. Then the main board would start clicking but she said box was still cooling. The f code usually means the main board is faulty.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

it will agitate and Darin but it will not spin at high speed

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

The compressor is running and pulling 1 amp. the condensing coil is clean and both fans are running. I installed a service valve, on the suction line, at the compressor. when i attached the gauges it immediately went to 29 inches of vacuum. I unplugged the unit and it stayed at the same value. in your opinion what does this indicate. i’m waiting on r134a to be delivered so I haven’t tried adding any refrigerant to this point.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

when I put the machine into spin it sounds like the engine of a plane taking off

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

do you have a video on how to replace the boot or bellow?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I had a customer with a Kenmore standup freezer and not getting enough cold on both food compartment and the freezer. We just replaced the control board and still having the same issue.
Your help is very critical. please assist.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views
f01

the customer states that when the machine is cold or warm then she gets the f01 but if it’s on HOT the machine works fine with out an error code

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

at first the ignitor would not Evan glow.
I checked the thermal fuse it was OL so I changed it now it will glow but will not light .
I checked the thermistor it is OK and the ignitor has 60 OHM
please advise.
the customer said they had an F70 error and now it will heat at all

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Need a electrical schematic for this refrigerator. I’m not getting power to the evaporator fan.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

THE COMPRESSOR IS DRAWING 1.4 AMPS AND ALL FANS ARE RUNNING. I INSTALLED A SERVICE VALVE ON THE PROCESS STUB AND IT IS READING 70 PSIG. I DON’T HAVE A VALVE ON THE HIGH SIDE. THE PRESSURE DOESN’T MOVE WHEN THE UNIT IS UNPLUGGED. THERE WEREN’T ANY SERVICE VALVES PRIOR TO ME ADDING THE ONE. IS THIS AN INDICATION OF A BLOCKAGE, BAD COMPRESSOR OR SOMETHING ELSE. I’M RELATIVELY NEW TO REFRIGERATION AS MOST OF MY EXPERIENCE IS WITH A/C. THE UNIT IS NOT COOLING AT ALL. THE COMPRESSOR FEELS VERY HOT AS WELL.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

I did some research and found a lot of different options… Oh by the way, I hate LG products, and I’ll never work on another one.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

I have been searching for different models of appliances and all I get is, videos not available, for example, model WRX735SDBM00 videos not available. And another is an LG model LFX31925ST-OO. When I am out on a job with a not cooling problem, I need help then.Please get back to me.
Thank You, Jim.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

What are the most common problems causing a GE profile to no cool properly ie 33 degrees in freezer and 50 degrees in refrigerator

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

I have a customer with an upright freezer. It stands taller than a regular fridge. Well I’ll get to the point. After diagnosing the problem, I proceeded to put the back evap cover panel back on AND I put the screw right thru the coil tubing. Ah s#~}%~~! I couldn’t believe that the screw hole was a 1/4 inch from the coil.
Well ” things happens” and it seems to happen to me an awful lot. The model / serial numbers that I gave to you, are barely readable, so I don’t even know IF they are correct. I offered to work something out with the customer, which turned out FOR ME to be a nightmare. She is a pack rat. It took me over an hour to remove the freezer from her house, because there was ONLY a path to get from one room to another. She had junk everywhere….
I took the freezer to a fellow repair tech that fixed the hole, blah blah blah. An hour after I dropped of her freezer, she called me to find out the status on it. One hour! I got several calls. So, I just stopped picking up the phone.
I offered to turn the case over to my insurance company but that was not an option…. So, I can’t tell you how many hours I spent trying to fix and satisfy this customer.
Here is my question, for further reference. I’m NOT going thru this again. Is there a website or something that I could use to determine the value of an appliance, and just pay the customer a fair price ?

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

Need a parts break down for this old refrigerator.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

Parts break down of unit.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Does control board operate every on the refrigerator?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

The dishwasher blue light will come on like it is going to start the cycle. I hear no noise and then the blue light goes off. when I open it, the cancel, drain light is on.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

The above washer is leaking from the tub seal and is loud in spin. I have not done this repair before but I’m thinking it is going to need the Kit support assembly. Part number WH16X10185. Has anyone done this repair? I would like to know if there are other parts I should be replacing as well. Looks like it has been leaking for a while. I’m familiar with changing out the mode shifter in other GE models but this is not quite the same and I did not find any good info on this repair. Thank you for any advise on this one.

0 votes
19k views

why does Kenmore upright freezer top shelf have a big big frost built up none of the other shelfs do this this is a very simple unit manual defrost no interior fan.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

replaced control part w108900094 and part wp12999401b and that did not solve problem can you help ?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
22k views

Top freezer working fine. Bottom fridge is too warm. Watched your video, took apart top panel, evaporator fan motor not working. dial switch in fridge makes no difference. I tested wires to evaporator motor fan, not getting any voltage to fan motor? The fridge has the dial switch that says “coldest to lowest”. took that panel down, it has the thermostat dial switch, and there is a white square thing with wiring harness connected to it next to the dial switch.
What would be stopping power from reaching the evaporator fan motor? FYI, this all happened after a power pole was hit in neighborhood, causing outage/spike. The condensor and it’s fan is running fine, freezer is working fine. Just not the fridge.

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

how do you take the door off to replace the soap dispenser?

  • Guest asked 9 years ago
  • last active 9 years ago
Showing 6301 - 6330 of 9k results