0 votes
8k views

HI FOLKS,

I AM GETTING THE ERROR CODE ER RF. THIS PERTAINS TO A FAN IN THE UNIT BUT WHAT FAN? THERE ARE THREE. I INTENED TO CHECK IT FROM THE MAIN BOARD NEXT WEEK BUT I WANT BE ON THE CORRECT PATH. ALL INFORMATIOIN GREATLY APPRECIATED.

NOTE: UNDER THE BRAND NAME I COULD NOT INSERT LG.

THANK YOU,
JAN
BARNEY’S APPLIANCE

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I am just starting in the appliance repair business and I would like to able locate schematics for appliance to practice reading schematics and I would like to know if there is a web site where I can access just schematics

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Customer wanted me to repair this front load washer, the control is missing. How can I tell which one it needs. there is about four different one , Please Help

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

got a combo Kenmore washer/dryer, there is a11/2inch gap between the washing basket and the body at the top causing articles to full into the washer and mess up the drive belt and speed sensor, the real question is where does the speed sensor and bracket attach and secondly if there should be a gap at the top.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

This is a double wall oven and only the top one is malfunctioning. The unit shuts off after 5 seconds of being turned on bake and the control board looks a bit stange. Could there be anything else other than the control board going wrong with this unit?

  • mytechjoe asked 9 years ago
  • last active 9 years ago
0 votes
3k views

How do you test the lid lock that it isn’t working?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Whirlpool has a bunch of kits listed on service matters for condensation and ice in icemaker room. For the model listed about which kit has had the most success getting rid of this problem. I am getting ice in the ice room fan
Thanks for your help

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

Having issue with maytag washer customer complains that lid lock lights stays on blinking, on arrival light was blinking try to cancel with cancel button no success, unplug and re-plug issue cleared, prior unplugging unit, unplugged the lid switch connection from the main board light still blinks. After unplugging and re-plugging the machine issue cleared did a cycle all went well, left the job customer call an hour later saying lid lock light blinking again. My thought bad control board, has anyone had this issue. Thanks in advance

0 votes
3k views

Towels still wet?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Door lock won’t stay latched and unit won’t go into spin.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Lady said ice maker water would not turn off. She lifted the bail on the I.M. and the water stopped. How do I know if it is the I.M. or the valve?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

so it started off with the f7 error i changed the board and the ribben but when i reconnected the unit to the outlet i hear the fan going on by itself

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

i changed the air damper and it still will not blow cold air to the fridge but when i open the freezer door i will get cold air in the fridge true the damper.
also there is alot of frost around the ice maker machine

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

the screen is fine i can set to go on and set the temp.
how ever there is no heat or gas flow the igniter will not ignite weather convection or not both broil and bake setting do not get flames

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

GOOD EVENING. I CHECKED OUT THE DISH WASHER AND WATER WAS NOT ENTERING. I PULLED IT OUT AND LAID IT ON THE DOOR AND REMOVED WATER INLET VALVE. I TOOK APART VALVE AND REASSEMBLED AND PUT 110 TO IT AND IT OPENED WHEN I BLEW THROUGH IT. REASSEMBLED AND REINSTALLED THE WASHER. WATER STARTED TO RUN LIKE NEW. GUESSING THE VALVE WAS CLOGGED OR LOSE CONNECTION. I THEN RECEIVED A CALL A DAY LATER THAT WATER WAS NOT DRAINING. ANY HELP WOULD BE GREAT AS I DO NOT HAVE A LOT OF EXPERIENCE WITH DISH WASHERS. THANKS, TODD FROM NY.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
2k views

Sounds like gears grainding. Is this a transmission problem?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Customer complaint of frost buildup inside chute of ice dispenser. The problem appears to be the flapper door does not close completely. Replacing the “door-ice” asm with flapper gives no better results. According to customer, this has been an ongoing problem with this refrigerator. Curious if anyone is familiar with this problem or a possible solution.

0 votes
3k views

not familiar with samsung ref drain icing up in ref section model Samsung ref , ref section drain ices up model rf217acrs

0 votes
4k views

We have a GE stack washer model listed above.
When turning the unit on “normal wash”. The washer will fill, does a brief agitate, pauses. It will stay in pause, you can restart it by pushing start/pause but, it will only agitate about a 1/2 second and pause again. In Spin cycle the unit will drain, start to spin then stops, with spin flashing the lid is locked. You cannot restart it from this point.
The error code says motor blocked but there is no apparent blockage.
Any help advice would sure be appreciated.
Thanks in advance

0 votes
2k views

I have A customer is stating that they are having ice maker issues with this samsung refrigerator in the model listed above in the subject line. I was curious if anyone had a fast track available for this model refrigerator. or service Manual

0 votes
3k views

I was recharging the compressor with refrigerant and the compressor was hot but during recharging the compressor just shut down.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

The cild air Only flow into the refrigerator through the damper when the freezer door is open when I close the freezer door and put my hand in the refrigerator near the damper there was no air flowing

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
2k views

I NEED TECH DOCUMENTS, SCHEMATICS, REFRIGERATION SHEETS PLEASE

  • Guest asked 9 years ago
  • last active 9 years ago
1 vote
3k views

Auto matic defrost control replaced, which looks like to me controls the defrost and damper control. Damper is wide open and isn’t working right. they don’t tell you how the control works with the new control board. There is no schematic. Also it doen’t tell you the resistance the damper control motor should be. No way to tell if the motor is good or the damper contol know is bad.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

I need a video on how to replace the slide rails om
n this unit. Matt had one out there but cannot find it

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

The ice maker is producing ice, but the ice won’t dispense. when actuator is pressed flap opens but auger doesn’t turn.what steps can I take to determine the problem?

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
3k views

Cust. has to keep reseting board by unplugging unit then plugging back in

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views
F30

I have changed the eoc and still get f30 the wires from the sensor all check good. The resettable thermal fuse was not tripped. The sensor is good ohms out the same as a new one. The last thing is the user interface . Is it a thing with this style of oven for both to go bad.

  • Guest asked 9 years ago
  • last active 9 years ago
0 votes
4k views

Need some extra eyes to take a look at this. Hopefully I can attach the information that is needed to try to determine how to properly wire this up.
Model of inline blower is VTI1010D

The hood and inline blower were installed in a house. New owner didn’t like it. Builder had it taken out and installed in another house. There is a connecting wire harness that runs between units. Naturally
that wiring harness could not be removed from original house. Electrician cut off the connecting end plugs to be able to match up wires. He wired it up and it don’t work. Builder saved the connecting ends, but that don’t help because
electrician took cut off wires out of plugs.

I have acquired information on wiring diagrams and schematics for hood and blower. I also find conflicting differences.
Here’s what I have come up with.

White wire from hood connects to blue wire at blower.
Brown wire from hood connects to brown wire at blower.
Red wire from hood connects to white wire at blower.
Blue wire from hood connects to red wire at blower.

Thanks in advance