The wash motor doesn’t turn on, water is coming in,
- Guest asked 7 years ago
- last active 7 years ago
doesn’t turn on to cook but the timer stills counts down like its cooking.
- T&G Appliance Repair asked 7 years ago
- last active 7 years ago
Getting error code e01 f01. Spin won’t start after sensing or maybe very short and slow spin. Did spin once very fast and only way to stop was unplug. Have unplugged for 10 minutes to try for reset and problem still there.
- Patrick's Appliance Service asked 7 years ago
- last active 7 years ago
I have a Kenmore front loading washer, about 8 yrs old, that has had what sounds like occasional bearing noise lately during the spin cycle. Today during the final high speed spin there was a bang and the drum slowed right down. I think it broke something… could this be related to the bearings? When I turned the machine off the drum didn’t seem to have a problem rotating back & forth very slowly for a while like it usually does at the end of a spin. If it is the drum bearings is it an expensive repair? — if it is I’m wondering if I’d be better off getting a new washer.
- Harley Clark asked 7 years ago
- last active 7 years ago
Hi techs. This kenmore refrigerator is actually a Frigidaire. The auger will not run nor will the crushed cube selection work unless you put it in the service mode. In the service mode all dispenser functions work. I have checked the micro switches, I have checked door switches , I have checked wiring harnesses in the door checked continuity to the wiring harnes in the freezer, I have changed the main board and the U.I. Board. Customer stated that you could slam the freezer door and it would some times work which made me think a bad wiring or loose connection. In test mode voltages are normal going to the auger and crushed cube solenoid. I have checked the connections at the top of the doors as well. What am I missing. Would appreciate your advice. Thank you.
- Guest asked 7 years ago
- last active 7 years ago
The burner and infinite switch part number is w10823734. The espy sensor harness on the old and new sensors won’t work on the new INF SWitch . or would it be simpler to use the old burner with the 12002121 INF SWITCH?
I need a wiring diagram. And any help you can give.
- Guest asked 7 years ago
- last active 7 years ago
This is an oven/microwave combo. Oven works fine and microwave works good except for it will not run longer than 1 minute. At that point, in the oven control board screen it will give an error code of F3E2. The microwave board doesn’t display this code. The oven sensors check fine as well as the oven works great! Not sure what this could be causing this as all works well except for the 1 minute time issue. Set for 3 minutes will cut off completely at 2 minutes. Any time frame will do the same.you can also start the microwave back up instantly and it will run for 1 minute. Any help would be great!!!
- Guest asked 7 years ago
- last active 7 years ago
Oven works but no burners on top do. Are they controled by the oven control somehow or what else could cause all of them to quit?
- Guest asked 7 years ago
- last active 7 years ago
Above items not working. Are they connected. Circuit wise? Please help with troubleshooting. Put it into diagnostic mode and it shows up with replace filter sign on first step. When I advance it to next step, it says order filter. When I check filter, it says it’s hundred percent. It’s been a big mystery. Thank you.
- mdhomeservices asked 7 years ago
- last active 7 years ago
After burner light up the spark ignitor continue to spark, this happen only on right front and right rear burners all others are fine.
- Guest asked 7 years ago
- last active 7 years ago
I need the troubleshooting steps for dishwasher please.
- Guest asked 7 years ago
- last active 7 years ago
i have customer who have Samsung induction range, and they got error E-84. keypad is not responding, i check the all control board and non of them have burning sign, i am planning to change touch pcb both side control board, i also download service manual and it says either invertor board or touch pcb board. how i can check inverter board without doing so much disassemble cook top remove. give me good plan to check
- Guest asked 7 years ago
- last active 7 years ago
I have a gas range that was flagged by the gas company CO levels to high. I have a detector but didn’t bring it with me ( I was informed it was a gas leak and just brought my sniffer) Visual inspection showed a normal blue flame in oven .It is in a small apartment with no vent and the gas company didn’t leave any ppm #s .what should I be looking for to feel confident it’s not the oven just the size of apartment and no ventilation?
- Guest asked 7 years ago
- last active 7 years ago
After make ice and fill bin start melting ice completely
- Guest asked 7 years ago
- last active 7 years ago
Do you have a video on how to remove the control panel.
- Guest asked 7 years ago
- last active 7 years ago
Water dispenser works fine. Replaced dual valve in door, power goes to valve but no water out of it to ice maker. Checked pilot valve in rear, has power to it for water dispenser, however no power going to pilot valve when ice maker tries to fill.
- Guest asked 7 years ago
- last active 7 years ago
Customer called for service on his icemaker…. after replacing the water valve to no avail, I found that the compartment in the ceiling with the icemaker and fan assembly was around 25-28°F, which I knew was too warm for the icemaker to operate. Yet, the bottom freezer compartment is well cold enough, in the single digits (2-5°F).
- Guest asked 7 years ago
- last active 7 years ago
The fan inside the Freezer behind the plastic grill spins against the back wall of the freezer causing a noise every time the fan comes on. It must be building up frost on it or something because it is intermittent. I dont know how to disassemble the unit and see whats going on. But it is loud and annoying.
- David Sutton asked 7 years ago
- last active 7 years ago
My GE MICROWAVE bejv177zla suddenly stopped working. I’ve replaced the fuse and used electronic cleaner spray on the door locks the clock is out Could it be the thermal fuse on the magnetron?
- Harley Clark asked 7 years ago
- last active 7 years ago
I have replace the otics and ice maker module customer still complaints still no ice production,
I have done force test and fill water in in ice maker but only makes that one batch of ice no more.
- Guest asked 7 years ago
- last active 7 years ago
This GE monogram dryer is a Challenge to disassemble. Please advise do you have a sheet or a video
- mrappliancepv asked 7 years ago
- last active 7 years ago
Ref is not cooling, no lights in the fresh food compartment and has a PF code. Previous tech replaced control board and user interface and still the same.
- mdhomeservices asked 7 years ago
- last active 7 years ago
Hello this specific issue is on a Kenmore dryer 796.81172210. The cooling light stays on and there is no heat. I have replaced heater which solved the heat issue but my question is why is the cooling light staying on??
I have experienced this issue many times in Samsung dryer especially once it’s fixed the heaters on and the light stays on after repair Any thought to why this is?
Is there a self diagnostic mode. If so please explaine how to use it.
- Guest asked 7 years ago
- last active 7 years ago
It quit freezing . Then the customer unplugged it. When I plugged it in the dispenser flap opened and closed and nothing else. When I press any button 88 88 and all the leds come on as long as I keep pressing the button and goes off when I release it. I can’t put it in any service mode.
Is one of the board’s bad? If so which one? What’s your advice?
- Guest asked 7 years ago
- last active 7 years ago
During spin cycle, it is very loud, as if the bearings are bad.
- Harley Clark asked 7 years ago
- last active 7 years ago
The control panel on our GE Profile Refrigerator is acting crazy. Lights are going on and off and non of the controls work.
- Hall Refrigeration asked 7 years ago
- last active 7 years ago
When opening the door on the microwave when it is still running it flips the breaker. A friend told us last night that should not be happening. Solutions?
- Hall Refrigeration asked 7 years ago
- last active 7 years ago
Happened before- went to tech sheet and reprogrammed board per trouble shooting guide. Dryer started working and has been working for approx. 4 months fine. Now back to same symptoms. Need help.
- Guest asked 7 years ago
- last active 7 years ago
Frigidaire combo laundry system, model FFLE3911QW0 stopped and I retrieved error code EC6. The entry from the tech sheet is pasted below. How should I troubleshoot this, or what are the likely causes of this?
- Guest asked 7 years ago
- last active 7 years ago